24 INSTALLATION
Checking Levelness
Once the dryer is in its final location, recheck the
dryer to be sure it is level. Make sure it is level
front to back and side to side, and that all four
leveling feet are in firm contact with the floor.

Installation Test (Duct Check)

Once you have completed the installation of the
dryer, use this test to make sure the condition
of the exhaust system is adequate for proper
operation of the dryer. This test should be
performed to alert you to any serious problems in
the exhaust system of your home.
• Your dryer features Flow Sense™, an innovative
sensing system that automatically detects
blockages and restrictions in dryer ductwork.
Keeping ductwork clean of lint buildup and free
of restrictions allows clothes to dry faster and
reduces energy use.
NOTE
• The dryer should be cool before starting
this test. If the dryer was warmed up during
installation, run the Air Dry cycle for a few
minutes to reduce the interior temperature.
Activating the Installation Test
1
Remove the literature, and then close the
door.
Do not load anything in the drum for this test,
as it may affect the accuracy of the results.
2
Press and hold the Wrinkle Care and Temp.
buttons and then press the Power button.
(On models with a glass touch control panel,
press the Power button then IMMEDIATELY
press and hold the Temp. and Wrinkle Care
buttons.) This button sequence activates the
installation test. The code 1N will display if the
activation is successful.
3
Press the START/PAUSE button.
The dryer will start the test, which will last
a few minutes. The heat will be turned on
and the temperatures in the drum will be
measured.
4
Check the display for results.
During the test cycle, monitor the Flow
Sense™ display on the control panel. If
the Flow Sense™ LED has not turned on
when the cycle ends, the exhaust system is
adequate. If the exhaust system is severely
restricted, the Flow Sense™ LED will turn on.
Other problems may also be shown with error
codes. See the chart on the next page for error
code details and solutions.
LED turned on:
RESTRICTED
5
End of cycle.
At the end of the test cycle, O will display. The
test cycle will end and the dryer will shut off
automatically after a short delay.