LG DLE3400 Series Owner's Manual page 21

Hide thumbs Also See for DLE3400 Series:
Table of Contents

Advertisement

Available languages

Available languages

• The dryer is configured for natural gas when
shipped from the factory. Make sure that the
dryer is equipped with the correct burner nozzle
for the type of gas being used (natural gas or
propane gas).
• If necessary, the correct nozzle (for the LP
nozzle kit, order part number 383EEL3002D)
should be installed by a qualified technician and
the change should be noted on the dryer.
• All connections must be in accordance with
local codes and regulations. Gas dryers MUST
exhaust to the outdoors.
NOTE
• In the Commonwealth of Massachusetts:
This product must be installed by a licensed
plumber or gas fitter. When using ball-type gas
shut off valves, they must be T-handle-type. A
flexible gas connector, when used, must not
exceed 3 feet.
This dryer is configured from the factory for natural
gas (NG). If the dryer is to be used with propane
(LP) gas, it must be converted by a qualified
service technician.
1
Make sure that the gas supply to the
laundry room is turned OFF and the dryer
is unplugged. Confirm that the type of gas
available in your laundry room is appropriate
for the dryer.
2
Remove the shipping cap from the gas fitting
at the back of the dryer. Be careful not to
damage the threads of the gas connector
when removing the shipping cap.
3
Connect the dryer to your laundry room's gas
supply using a new flexible stainless steel
connector with a 3/8-inch NPT fitting.
NOTE
• DO NOT use old connectors.
4
Securely tighten all connections between the
dryer and your laundry room's gas supply.
5
Turn on your laundry room's gas supply.
6
Check all pipe connections (both internal and
external) for gas leaks with a noncorrosive
leak-detection fluid.
7
Proceed to Venting the Dryer.
3/8" NPT gas
Connection
AGA/CSA-Certified
Stainless Steel Flexible
Connector
High-Altitude Installations
The BTU rating of this dryer is AGA-certified for
elevations below 10,000 feet.
If your gas dryer is being installed at an elevation
above 10,000 feet, it must be derated by a
qualified technician or gas supplier.
INSTALLATION
21
1/8" NPT Pipe Plug
Gas Supply Shutoff
Valve