Pin Description - Ublox ZOE-M8B Series System Integration Manual

Ultra-small, super low power u-blox module
Table of Contents

Advertisement

2.8 Pin description

Pin #
Name
I/O
A1
GND
A2
SDA / SPI CS_N I/O
A3
GND
A4
RF_IN
I
A5
GND
A6
Reserved
I/O
A7
GND
A8
GND
A9
GND
B1
SCL / SPI CLK
I
B9
GND
C1
SQI_D1
I
C3
PIO11
I/O
C4
SAFEBOOT_N
I
C5
LNA_EN
O
C6
PIO15
I/O
C7
GND
C9
GND
D1
SQI_D0
I/O
D3
SQI_CS_N
I/O
D4
D_SEL
I
D6
GND
D9
GND
E1
SQI_CLK
I/O
E3
SQI_D2
I/O
E7
GND
E9
Reserved
I/O
F1
Reserved
I/O
F3
SQI_D3
I/O
F4
Reserved
I/O
F6
PIO14
I/O
F7
GND
F9
Reserved
I/O
G1
VCC
I
G3
GND
G4
PIO13 / EXTINT I
G5
Reserved
I/O
G6
GND
G7
GND
UBX-17045131 - R04
Production Information
Description
Ground
Serial interface.
Ground
GNSS signal input
Ground
Reserved. Do not connect.
Ground
Ground
Ground
Serial interface.
Ground
Data line 1 to external SQI flash memory or
reserved configuration pin.
Digital I/O
Used for programming the SQI flash memory
and testing purposes.
LNA on/off signal connected to internal LNA
Digital I/O
Ground
Ground
Data line 0 to external SQI flash memory or
reserved configuration pin.
Chip select for external SQI flash memory or
configuration enable pin.
Interface selector
Ground
Ground
Clock for external SQI flash memory or
configuration pin.
Data line 2 to external SQI flash memory or
reserved configuration pin.
Ground
Reserved
Reserved
Data line 3 to external SQI flash memory or
reserved configuration pin.
Reserved
Digital I/O
Ground
Reserved
Supply voltage
Ground
External interrupt
Reserved
Ground
Ground
Contents
ZOE-M8B - System Integration Manual
Remark
Ensure good GND connection
See section 0
Ensure good GND connection
See section 2.5
Ensure good GND connection
Must be left open!
Ensure good GND connection
Ensure good GND connection
Ensure good GND connection
See section 0
Ensure good GND connection
Leave open if not used.
Leave open if not used.
Leave open if not used.
Leave open if not used.
Leave open if not used.
Ensure good GND connection
Ensure good GND connection
Leave open if not used.
Leave open if not used.
See section 0
Ensure good GND connection
Ensure good GND connection
Leave open if not used.
Leave open if not used.
Ensure good GND connection
Do not connect. Must be left open!
Do not connect. Must be left open!
Leave open if not used.
Do not connect. Must be left open!
Leave open if not used.
Ensure good GND connection
Do not connect. Must be left open!
Clean and stable supply needed
Ensure good GND connection
Leave open if not used.
Do not connect. Must be left open!
Ensure good GND connection
Ensure good GND connection
Page 21 of 42

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zoe-m8b gnss sipZoe-m8b-0-10

Table of Contents