FR
4. OPERATION
ES
The charger will communicate with the battery pack to evaluate
the condition of the battery pack.
PT
IT
Note: Press the light button to check the battery pack
whether needs to charge.
EL
PL
Four green lights on
RU
Three green lights on
KZ
UA
Two green lights on
RO
One green light on
BR
EN
One red light on
Note:
button may display a lower charge than it will if checked a few
minutes later. The battery cells "recover"some of their charge after
resting.
HOW TO REMOVE THE BATTERY PACK FROM THE CHARGER
Disconnect the power supply from the charger.
Remove battery pack from the charger.
242
CHARGING INDICATOR
Lights
Lights Indicator
Immediately after using the battery pack, the charge level
Status
The battery is at full capacity
«OK to store»
The battery is at 75% capacity
«OK to store»
The battery is at 50% capacity
and requires to be charged
«Optimized charge for long
storage»
The battery is at 25% capacity
and requires to be charged
«OK for storage»
The battery is at 10% capacity
and requires to be charged as
soon as possible
«Not OK for long term storage»
Need help?