6. Slide the multi-meter off the screws and flip it over. There is a small latch tab on the bottom. Press the tab (red
arrow) to release the latch, and slide the connector apart. See Figs. 6 & 7 below.
Fig. 6: Press tab to release latch.
INSTALLING THE NEW MULTI-METER
7. Follow the steps above in reverse (connect the connector, mount the meter, re-install and tighten the nuts.
8. When re-mounting the panel, mount two or three of the panel-mounting screws (red arrows, Fig. 3) to hold the
panel in position, but do not tighten them down.
9. Re-install the 3-in-1 knob in the same orientation as you removed it. Make sure, after tightening the mounting
screw, that it operates properly.
10. Install the other panel-mounting screws and tighten all screws.
11. Re-connect the spark plug boot and the negative battery wire according to the instructions in your owner's
manual.
12. Power up the generator and make sure everything operates properly.
Contact WEN Customer Service at 1-800-232-1195, M-F, 8-5 CST, or email
QUESTIONS? PROBLEMS?
techsupport@wenproducts.com
Fig. 7: Connectors separated.
Date last modified: 2020/07/01