SOME NOTES ABOUT POWER CORDS
Refer to the following chart in determining the necessary gauge extension cord for each of your devices. Round up
to the higher amperage in the chart to maximize safety.
Device Requirements
Amps
Watts
(120V)
2.5
300
5
600
7.5
900
10
1200
15
1800
20
2400
25
3000
30
3600
40
4800
*NR = Not Recommended
WARNING! Generator should only be connected to electrical devices, either directly or with an extension
cord. NEVER CONNECT TO A BUILDING ELECTRICAL SYSTEM without a qualified electrician and connected to
a transfer switch as a separately derived system. Such connections must comply with local electrical laws and
codes. Failure to comply can create a back-feed, which may result in serious injury or death to utility workers.
NOTE: For power outages, permanently installed, stationary generators are better suited for providing backup
power to your home. Even a properly connected portable generator can become overloaded. This may result in
overheating or stressing the machine's components, possibly leading to generator failure.
22
USING YOUR GENERATOR
RED
(OVERLOAD)
OFF
Generator output is normal.
Flashing continuously
Generator is exceeding rated output.
Flashes 1x, repeating
Voltage at alternator is too low. No elec-
every 3 sec
trical output.
Flashes 2x, repeating
Engine speed is too low. No electrical
every 3 sec
output.
Flashes 3x, repeating
Inverter temperature is too high. No
every 3 sec
electrical output.
Flashes 5x, repeating
Voltage at alternator is too high. No
every 3 sec
electrical output.
Flashes 6x, repeating
Generator has exceeded rated output and
every 3 sec
cut off power to protect itself. No electri-
cal output.
Watts (240V)
600
1200
1800
2400
3600
4800
6000
7200
9600
MEANING
Max. Cord Length (ft) by Wire Gauge
#8 wire
#10 wire
NR
NR
NR
NR
NR
350
NR
250
NR
150
175
125
150
100
125
65
90
NR
RESOLUTION
No action needed.
Reduce load on generator.
Check for loose connections. Call
1-800-232-1195 for assistance.
Check carburetor and stepper motor.
Ensure Eco-Mode is OFF. Have genera-
tor serviced; call 1-800-232-1195 for
assistance.
Turn generator off and let it cool down
fully (1 – 2 hours) before restarting.
Have generator serviced; call 1-800-
232-1195 for assistance.
Turn OFF and disconnect loads. Press
RESET button on panel. Reduce load on
generator.
#12 wire
#14 wire
NR
375
300
200
200
125
150
100
100
65
75
50
60
NR
NR
NR
NR
NR
Table 3 - Power Cord Requirement Guide
#16 wire
250
125
100
50
NR
NR
NR
NR
NR