12 Appendix A2: Minimum lubricant unit

Scope of delivery
Minimum lubricant unit (B)
Attachment screw (A)
Air tube with quick fitting coupling (C)
Installation
Mount the lubricant unit (B) with the
screws (A) at the rear side of the
machine.
Connect the electrical connection line (E)
with the connector (F) with the machine.
Connect the compressed-air hose (C)
with the fitting (D).
Connect the compressed-air hose (C) to
the commpressed-air.
Compressed-air (58 - 87psi / 4 - 6bar)
cleaned with steam trap!
Commissioning
(G)
Lubricant tank
(G1) Cover for lubricant tank
(H1) Flow controller for dosing pump
(H2) Clamp lever for quantity controller
(H3) Indicator dose quantity
(I)
Adjusting screw for lubricant air
(J)
Adjusting screw for air output
(K)
Nozzle for lubricant and air
Wearing eye protection is obligatory!
300 / 400 / 900
lubricant pulse, air pulse, air cleaning pulse
A
B
C
G.1
G
H1
I
user manual
G.1
F
E
D
J
H3
H2
K
55