General

Dear Customer,
Read this instruction manual carefully before you
start using the oven. This will enable you to become
familiar with how to use the unit quickly.
Take care when operating the sauna oven
When operating the sauna oven remember that it
reaches very high temperatures.
The sauna oven becomes particularly hot around the
top section of its frame.
Children should therefore be kept well away from it
since they will not necessarily recognize the dangers
that may be involved with using this unit. Our ovens
comply with the latest safety regulations. However,
these regulations do not necessarily cover every
possible accident risk. To ensure that your oven can
be used safely, you should pay close attention to the
safety instructions in the appropriate section of this
manual.

Important safety instructions

Whilst your sauna oven is operating, very high
temperatures will be created in the booth and above
all on the oven itself. If it is not installed correctly
there is a risk of fire. Read these installation
instructions carefully. Pay special attention to the
dimensions and the instructions listed below.
The SHG 7.5 kW SHG 9.0 kW, SHG 7.5 kW with
evaporator and SHG 9.0 kW with evaporator
Remove
sauna ovens are designed for a connection
backing foil
voltage of 400 V AC 3 N.
before you
The installation and the electrical connection of
start the
the sauna equipment and other electrical
oven
equipment must be carried out by a trained
electrician. Special attention must be paid to the
safety measures set out in VDE 0100 § 49 DA/6
and VDE 0100 Part 703/11.82 §4 during this
work.
Sauna equipment may only be installed in sauna
booths made of suitable, low-resin and untreated
material (for example nordic spruce).
The minimum height of the sauna booth must be
1.75 m (interior height).
Important: The moisture protection package in
the oven's connection box must be removed (fire
risk).
Only a sauna oven with the appropriate heating
capacity may be installed in the sauna booth.
Connection rating
Ventilation slits must be provided in all sauna
booths.
The venting point must always be positioned at a
diagonal to the rear sauna wall at the bottom.
The ventilation slits must not be sealed.
The control unit required for controlling and
regulating the sauna oven must be installed on
the exterior wall of the booth, whilst the sensor
casing must be installed inside the sauna booth
as detailed in the enclosed installation
instructions.
The booth light and its installation must be in a
„splash-proof" design and suitable for an ambient
temperature of 140°C. Therefore only a VDE-
approved sauna light with a maximum rating of
40 W may be installed with the sauna oven.
11.12.2007
10:33 Uhr
Booth size
[kW]
3.6
approx. 4 - 6
7.5
approx. 8 - 12
9.0
approx. 10 - 14