Modification, spare parts manufacturing / Unproven usage / Scope of delivery / Application
1.3 Unilateral modification and spare parts manufacturing
Modifications or changes to the unit/installation should only be carried out after
consultations with the manufacturer. Original spare parts and accessories authori-
sed by the manufacturer are essential for compliance with safety requirements. The
use of other parts can invalidate any claims for warranty or compensation.
The operating safety of the unit is only guaranteed provided that the unit is used in
accordance with this operating instructions. The limit values given hereafter
should under no circumstance be exceeded. These operation instructions do not
supersede or exclude the following of generally valid regulations and standards.
KBN: FLOWTP30
Submersible pump, ready for plugging in, with 10 m cable with
adjustable float switch, 1½" pressure outlet with female thread and 1¼" pressure
outlet with male thread.
KBN: FLOWTP30 OS
Submersible pump, ready for plugging in, for switchgear operation, with 10 m cable , Schuko
plug, 1½" pressure outlet with female thread and 1¼" pressure outlet with male thread.
>
FLOW submersible pump 30 series is suitable for pumping clear water, rainwa-
ter, domestic wastewater without faecal matter, and a solids content up to
0.5 % max. (maximum solids passage of diameter 30 mm).
>
The pumps may not be used to pump cor rosive, flammable , gaseous or potenti-
ally explosive fluids or sewage containing faecal matter. Fluids containing sand
or other abrasive substances reduce the service life of the pumps.
>
The noise emission value is less than 70 dB (A).
GC-P-FLOW-30-12-1101-JH1.indd 17
1.4 Unproven usage
2. Scope of delivery
3. Application
17
o plug, built-in
02.03.15 14:04