Hardwire conversion kit

Advertisement

Terminals 3‐10 on the super switch correspond to zones 1‐
NOTE:
8. For example, wire the positive (HI) side of zone 1 on the 
Super Switch to terminal 3.
Repeat the steps above for each additional zone.
3
4
Group the LO/(GND) wires together and connect them to terminal 
1/G (GND) of the Super Switch. 
5
Replace the front cover on the Super Switch.
Ensure the power supply is mounted in the enclosure included 
6
with the 2GIG‐TAKE‐KIT1. 
Position the backup battery in the recommended location in the 
7
enclosure.
Figure 5 Recommended Location for Backup Battery (Not Included)
A Backup Battery
8
Connect the Super Switch to the backup battery as follows:
Connect the RED (BAT+) wire from the Super Switch to the RED 
8a
terminal on the backup battery.
Connect the BLACK (BAT ‐) wire from the Super Switch to the 
8b
BLACK terminal on the backup battery.
Connect the Power Supply wires to the backup battery as follows:
9
9a
Connect the RED (BAT +) and BLACK (BAT ‐) wires (provided) 
from the power supply to the BAT + and BAT ‐ terminals on the 
Power Supply Board. 
Connect the Spade Lugs to the Power Supply Ground and 12 V 
9b
wires to the corresponding Quick Disconnect Connectors on 
the Super Switch wires. The Super Switch should already be 
connected to the backup battery.
9c
Connect the 16.5V AC leads for the transformer to the 16.5V 
Power Supply. 
NOTE:
To avoid potential damage to the transformer and 
connected devices, measure the transformer's output voltage 
before connecting it to the Power Supply Board.
IMPORTANT:
To avoid nuisance low battery indicators from 
connected zones, always power up the battery before 
connecting AC power. If you experience an issue, see 
Troubleshooting the Low Battery Alert.
Connect the 16.5 V AC leads to the AC terminals on the Power 
10
Supply Board. 
Hardwire Conversion Kit (2GIG-TAKE-KIT1) | Installation Instructions
Connect the plug‐in transformer (included) into an unswitched 
11
wall outlet. 
Prepare to secure the transformer to the outlet as follows:
12
• For a standard wall outlet, screw the transformer to the outlet. 
The screw is included with the plug‐in transformer. 
OR
• For a decora wall outlet, affix the double‐sided adhesive tape 
to the transformer. Then adhere the transformer to the outlet. 
Figure 6 Connecting Power to the Hardwire Conversion Kit
A Wall Outlet
B Plug‐in Transformer and Screw (included) 
C Plug‐in Transformer and Double‐Sided Adhesive Tape (included) for Decora 
Outlets
D Back‐side of Plug‐in Transformer with Double‐Sided Adhesive tape affixed
Recommended Maximum Current Draw
The maximum current draw from external devices shall not exceed 
the recommendations in the table below:
When this number of Super Switch 
Modules are installed:
Three (3) Modules
Two (2) Modules
One (1) Module
Troubleshooting the Low Battery Alert
If a low battery alert appears:
1
Unplug the transformer to power down the Power Supply.
Remove all connections from the battery. 
2
3
Test the battery's voltage with a battery life test meter (not 
multimeter). 
4
If the battery is fine, rewire the Super Switch. 
After rewiring the Super Switch, reconnect the battery 
5
connections, connect power to Terminal 2 on the Super Switch, 
and then plug in the transformer.
NOTE:
To clear the low battery alert, you may need to open and 
close all of the zones or to reboot the Control Panel. To reboot 
the panel, go to the Installer Toolbox, press System 
Configuration, and the press End at the question screen. 
When the Summary of System Configuration screen appears, 
ensure the Save Changes box is selected. Then press Exit.
NOTE:
All of the ground wires must be grouped together and 
connected to the ground port of the Super Switch.
Do not exceed this maximum:
350 mA