Hardwire Conversion Kit (2GIG-TAKE-KIT1) | Installation Instructions
Figure 2 Mounting the Enclosure to the Wall
A One (1) Removable Cover
B Hinge Pins
C Four (4) Keyhole Slots
D Four (4) Plastic Wall Anchors (included)
E Four (4) Phillips Head Screws (included)
F Two (2) Access Holes
G One (1) Optional Knockout
Mounting the Power Supply Board in the
Enclosure
To mount the power supply board inside the enclosure:
1
Attach the three (3) double‐stick foam strips (included) to the flat
surfaces on the back edges of the power supply board.
As shown in positions A and B in the figure below, do not affix the
foam strips over the edge with the exposed pins.
2
Affix the board to the lower‐right corner of the enclosure.
For safety, ensure that the board is not covering the wiring
NOTE:
access or keyhole slots. See C in the figure below.
3
(Optional) Use four (4) sheet metal screws (not included) to secure
the power supply board to the enclosure.
NOTE:
To avoid damaging the board, do not overtighten the
screws.
Figure 3 Mounting the Power Supply Board
A Three (3) Double‐Stick Foam Strips (Affix to Power Supply Board)
B Power Supply Board (Do not affix foam strips over exposed pins)
C Power Supply Board (Affix to back of enclosure)
2
Copyright © 2014 Linear LLC.
Mounting the Super Switch in the Enclosure
To mount the Super Switch inside the enclosure:
Attach the adhesive backing to the back side of the plastic wall
1
bracket for the Super Switch.
The adhesive backing is included in the Hardwire Conversion Kit.
Affix the plastic wall bracket to the upper‐right corner of the
2
enclosure. See position 3 in Figure 4 Mounting the Super Switch in
the Enclosure.
If installing more than one (1) Super Switch module,
NOTE:
mount each plastic wall bracket vertically as shown in Figure
4. The enclosure can house a maximum of three (3) modules.
Use the two (2) sheet metal screws (included with the Super
3
Switch) to secure the module to the inside the enclosure.
Slide the backplate of the Super Switch downwards over the
4
mounting stubs on the face of the plastic wall bracket.
To remove the Super Switch backplate from the plastic wall
5
bracket, slide the backplate in an upwards direction to release it
from the bracket's mounting stubs.
Figure 4 Mounting the Super Switch in the Enclosure
A Super Switch Module(s)
B Plastic Wall Bracket(s) (brackets affixed vertically to back of enclosure)
C Double‐sided Adhesive Tape (included) and/or Optional Screws for Plastic Wall
Bracket
D Super Switch Backplate, Printed Circuit Board, and Wiring
E Super Switch Front Cover
Wiring the Components
Wiring must always be installed by qualified service personnel and in
accordance with National Electrical Code, as well as with all local
codes and authorities having jurisdiction.
The Hardwire Conversion Kit is intended for indoor use
NOTE:
only.
To wire the components in the kit:
Connect the Ground and 12V wires from the Super Switch to the
1
+V and NEG terminals on the Power Supply Board.
Refer to the wiring diagram in Figure 3 "Hardwire
NOTE:
Conversion Kit Wiring" on page 4.
2
Attach the positive (HI) side of each wire to the corresponding
zone on the super switch terminal block.