Download Print this page

Mitsubishi Electric MFZ-KT25VG Installation Manual page 6

Floor type air conditioners
Hide thumbs Also See for MFZ-KT25VG:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
2-4. INDOOR UNIT INSTALLATION
2-4-1. INSTALLING THE INDOOR UNIT ON THE FLOOR
1) Place the indoor unit on the flat floor.
2) Fix the indoor unit at 4 points with the included wood screws (9) and washers
(10). Tighten the screws securely.
2-4-2. MOUNTING THE INDOOR UNIT ON THE WALL
1) Hook the top of the indoor unit on the indoor unit mounting bracket (7).
2) Fix the indoor unit at 4 points with the included wood screws (9) and washers
(10). Tighten the screws securely.
2-4-3. EMBEDDING THE INDOOR UNIT IN A WALL
1) Make a hole in the wall.
2) Using reinforcement material, adjust the depth.
3) Remove 6 screws that fix the base to the unit. Remove the base from the unit.
EN
4) Fix the indoor unit at 4 points with the included wood screws (9) and washers
(10). Tighten the screws securely.
2-5. CONNECTING WIRES FOR INDOOR UNIT
1) Remove VA clamp.
2) Pass indoor/outdoor unit connecting wire (A) from the back of the indoor unit
and process the end of the wire.
3) Loosen terminal screw, and connect first the earth wire, then indoor/outdoor
unit connecting wire (A) to the terminal block. Be careful not to make mis-
wiring. Fix the wire to the terminal block securely so that no part of its core is
appeared, and no external force is conveyed to the connecting section of the
terminal block.
4) Firmly tighten the terminal screws to prevent them from loosening. After
tightening, pull the wires lightly to confirm that they do not move.
5) Secure indoor/outdoor unit connecting wire (A) and the earth wire with the VA
clamp. Never fail to hook the left claw of the VA clamp. Attach the VA clamp
securely.
• Make earth wire a little longer than others. (More than 45 mm)
• For future servicing, give extra length to the connecting wires.
• Do not fold the excess wire, or cram it into small space. Take caution not to
damage the wires.
• Be sure to attach each screw to its correspondent terminal when securing
the cord and/or the wire to the terminal block.
When installing the unit, securely connect the refrigerant pipes before
starting the compressor.
EN-5
WARNING
705
Unit
4
4
Base
3
3
3
3 3
3
VA clamp
Terminal block
Fixing screw
Indoor/outdoor unit
connecting wire (A)
Earth wire
(green/yellow)
15 mm
Indoor/outdoor unit
35 mm
connecting wire (A)
Lead wire
Reinforcement
material
Indoor terminal block
Outdoor terminal block

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Mfz-kt35vgMfz-kt50vgMfz-kt60vg