1 Overview
„ Response results format
07, 00, 00, 01, 00/ 00, 00, 00, 00/ 5e, 00, 00, 00/ 0d, 0a, 00, 00 ·
Communication speed
Data length
* Reserved indicates unused areas which are always "00".
When the setting values for each item from the response results format are compared, they will be as shown in the follow-
ing table.
Item
Setting value
Communication speed
07
Data length
00
Parity
00
Stop bits
01
Flow control
00
* Check each of the detailed setting values from the setting values by referring to the WB1F user's manual.
6
Exit the WB1F Support Tool and then turn off the power supply for the WB1F.
7
Turn on the power supply for the WB1F, and then run the WB1F Support Tool.
8
On the Connection Settings screen, set the detailed setting values that were determined in step 5, and then
click Connection.
* At this time, the uppercase response is not used.
2 Operational Check
Parity
Flow control
Check digit
Stop bits
Reserved*
Detailed setting
value
115200 bps
7 bit
NONE
2 bit
None
4-3
3 Window and Menu
Reserved* Pre x
Uppercase response
Item
Setting value
Check digit
00
Uppercase response
00
Prefix
5e,00,00,00
Suffix
0d,0a,00,00
4 Appendix
Troubleshooting
Su x
Detailed setting
value
Disabled
Disabled (lowercase)
^
CR
LF