Water Connection - Firex BETTERPAN UDBRG A V1 Series Installation And Operation Manual

Rectangular pressure bratt pans, gas type
Hide thumbs Also See for BETTERPAN UDBRG A V1 Series:
Table of Contents

Advertisement

01-UDBRG.A_V1-DIMU-00-EN
Replace the cover and secure it with screws.
Any damage caused by water/steam infiltration or insects, due to the machine panels
not being closed (after installation or maintenance) shall void any warranty claims.
7.2

WATER CONNECTION

The equipment is to be installed with adequate backflow protection to comply with
applicable federal, state, and local codes.
The water pressure in the supply network must be between the values indicated in the
"INSTALLATION TECHNICAL DATA" table.
If not, install a pressure reducer upstream of the appliance.
Before making the water connection, carefully clean the connection pipe. It is
advisable to let the water flow to clean the whole piping. Any impurities could
compromise the operation of the machine.
The diameter of the connections is indicated in "INSTALLATION TECHNICAL DATA"
The connection point is indicated in the "PLANT CONNECTION"
Install a shut-off valve upstream of the appliance, one for each water connection on the appliance, near the
appliance and in a position easily accessible by the user.
30
CONNECTIONS

Advertisement

Table of Contents
loading

Table of Contents