Valve Operating Time Table For Rotary Actuator (Quarter-Turn) - Emerson Bettis BHH Series Installation, Operation And Maintenance Manual

Hydraulic double-acting balanced rotary actuator 90 quarter-turn
Table of Contents

Advertisement

Section 12: Valve Time Adjustment
December 2019
12.1.1
Valve Operating Time Table for Rotary Actuator
(Quarter-Turn)
Table 6.
Valve Size
A
≤100A (4")
125
150
200
250
300
350
400
450
500
1. The operating time recommended in this table is made based on 1 to 3 seconds per inch (not
minimum or maximum time, this mean variable tolerances) under normal ambient temperature.
NOTE:
When the operating time is set at the actual ambient temperature, it may not correlate
with the set time in the table due to the viscosity characteristics at different temperatures.
39
Installation, Operation and Maintenance Manual
Recommended
operating time
(seconds)
B
< 10
5
5 -15
6
6 - 18
8
8 - 24
10
10 - 30
12
12 - 36
14
14 - 42
16
16 - 48
18
18 - 54
20
20 - 60
MAN-02-05-62-0742-EN Rev. 0
Valve Size
Recommended
operating time
A
B
550
22
600
24
650
26
700
28
750
30
800
32
850
34
900
36
1000
40
> 1000 (40")
(seconds)
22 - 66
24 - 72
26 - 78
28 - 84
30 - 90
32 - 96
34 - 102
36 - 108
40 - 120
> 120
Valve Time Adjustment

Hide quick links:

Advertisement

Table of Contents
loading