5. POWER SUPPLY EQUIPMENT
P10 [FAN-R] (JAPAN SOLDERLESS TERMINAL MFG. CO., LTD. PHR-3)
Pin no.
1
+24V
2
Fan lock error signal
3
0V
P11 [HATOME] (JAPAN SOLDERLESS TERMINAL MFG. CO., LTD. PHDR-12VS)
Pin no.
1
-
2
-
3
-
4
-
5
θ-axis PM clock signal
6
θ-axis PM direction signal
7
θ-axis PM save signal
8
θ-axis PM excitation signal
9
+5V
10
+5V
11
0V
12
0V
P12 [POWER] (JAPAN SOLDERLESS TERMINAL MFG. CO., LTD. VHR-7N)
Pin no.
1
+5V
2
+24V
3
0V
4
+55V
5
+55V
6
0V (P0V)
7
0V (P0V)
P13 [DC55] (JAPAN SOLDERLESS TERMINAL MFG. CO., LTD. VHR-2N)
Pin no.
1
+55V
2
0V (P0V)
P14 [UVW] (MOLEX3191-03R1)
Pin no.
1
Machine motor U phase
2
Machine motor V phase
3
Machine motor W phase
P15 [DC300] (MOLEX3191-02R1)
Pin no.
1
0V (for machine motor)
2
+300V
91
Signal name
Signal name
Signal name
Signal name
Signal name
Signal name
Probable symptoms due to poor contact
• Error code E93 appears.
Probable symptoms due to poor contact
• Rotation motion of feed mechanism is not correct.
• θ-axis position can not be found.
• Error code E52 or E82 appears.
Probable symptoms due to poor contact
• Power does not come on.
• Feed bracket does not move.
• Machine operation becomes unstable.
• Home position can not be found.
• Error code E80 appears.
Probable symptoms due to poor contact
• Feed bracket does not move.
• Home position can not be found.
• Error code E80 appears.
Probable symptoms due to poor contact
• Machine motor does not run.
• Rotation of machine motor is not correct.
• Error code E70 or E91 appears.
Probable symptoms due to poor contact
• Machine motor does not run.
• Rotation of machine motor is not correct.
• Error code E70 or E91 appears.