OPERATION
2. Correct the diameter
Check the depth of cut by making a trial cut
and correct the setting if need be.
The cut should stop 0.1 – 0.3 mm in front of the conductor
so as not to damage it.
Blades are at sufficient safety spacing
from the conductor and remove the
insulation with a clean cut.
Blades cut too deep into the conductor.
Blade may be damaged!
Blades do not penetrate the insulation to
sufficient depth.
Blade may be damaged!