Setting
Pr.
Name
range
Speed control integral
821
0 to 20s
time 1
822
Speed setting filter 1
0 to 5s, 9999
Torque control P gain 1
824
(current loop
0 to 500%
proportional gain)
Torque control integral
825
time 1 (current loop
0 to 500ms
integral time)
827
Torque detection filter 1 0 to 0.1s
828
Parameter for manufacturer setting. Do not set.
Speed control P gain 2 0 to 1000%,
830
9999
Speed control integral
831
0 to 20s, 9999 9999
time 2
832
Speed setting filter 2
0 to 5s, 9999
834
Torque control P gain 2 0 to 500%, 9999 9999
Torque control integral
0 to 500ms,
835
time 2
9999
837
Torque detection filter 2 0 to 0.1s, 9999 9999
Analog input offset
849
0 to 200%
adjustment
Terminal 4 function
858
0, 4, 9999
assignment
0 to 500A,
9999

Torque current/Rated
859
PM motor current
0 to 3600A,
9999

0 to 500A,
Second motor torque
9999

860
current/Rated PM
0 to 3600A,
motor current
9999

864
Torque detection
0 to 400%
Torque monitoring
866
0 to 400%
reference
867
AM output filter
0 to 5s
Terminal 1 function
868
0, 4, 9999
assignment
869
Current output filter
0 to 5s
Speed detection
870
0 to 5Hz
hysteresis
Input phase loss
872
0, 1
protection selection
874
OLT level setting
0 to 400%
Regeneration
882
avoidance operation
0 to 2
selection
Regeneration
883
avoidance operation
300 to 1200V
level
Regeneration avoidance
884
at deceleration detection
0 to 5
sensitivity
Regeneration avoidance
0 to 590Hz,
885
compensation frequency
9999
limit value
Regeneration
886
avoidance voltage gain 0 to 200%
888
Free parameter 1
0 to 9999
889
Free parameter 2
0 to 9999
Cumulative power
891
0 to 4, 9999
monitor digit shifted times
892
Load factor
30 to 150%
Energy saving monitor
0.1 to 55kW
893
reference (motor
0 to 3600kW
capacity)
Control selection during
894
commercial power-
0 to 3
supply operation
Power saving rate
895
0, 1, 9999
reference value
896
Power unit cost
0 to 500, 9999 9999
Power saving monitor
0, 1 to 1000h,
897
average time
9999
Power saving cumulative
898
0, 1, 10, 9999 9999
monitor clear
Operation time rate
0 to 100%,
899
(estimated value)
9999
900
CA terminal calibration ―
901
AM terminal calibration ―
Terminal 2 frequency
902
0 to 590Hz
setting bias frequency
Terminal 2 frequency
902
0 to 300%
setting bias
903
Terminal 2 frequency
0 to 590Hz
(125)
setting gain frequency
Terminal 2 frequency
903
0 to 300%
setting gain
Terminal 4 frequency
904
0 to 590Hz
setting bias frequency
Terminal 4 frequency
904
0 to 300%
setting bias
905
Terminal 4 frequency
0 to 590Hz
(126)
setting gain frequency
Terminal 4 frequency
905
0 to 300%
setting gain
Initial
Pr.
Name
value
Terminal 1 bias
0.333s
917
frequency (speed)
9999
917
Terminal 1 bias (speed) 0 to 300%
Terminal 1 gain
918
50%
frequency (speed)
918
Terminal 1 gain (speed) 0 to 300%
Terminal 1 bias
919
40ms
command (torque)
919
Terminal 1 bias (torque) 0 to 300%
0s
Terminal 1 gain
920
command (torque)
9999
920
Terminal 1 gain (torque) 0 to 300%
Current output bias
930
signal
Current output bias
930
9999
current
Current output gain
931
signal
9999
Current output gain
931
current
Terminal 4 bias
100%
932
command (torque)
932
Terminal 4 bias (torque) 0 to 300%
0
Terminal 4 gain
933
command (torque)
933
Terminal 4 gain (torque) 0 to 300%
9999
PID display bias
934
coefficient
PID display bias analog
934

value
9999
PID display gain
935

coefficient
150%
PID display gain analog
935
value
150%
Parameter copy alarm
989
0.01s
release
0
990
PU buzzer control
991
PU contrast adjustment 0 to 63

0.02s
992
Parameter for manufacturer setting. Do not set.
0Hz
997
Fault initiation
PM parameter
998
0

initialization
Automatic parameter
110%
999

setting
1000
Direct setting selection 0 to 2
0
Lq tuning target current
1002
adjustment coefficient
940VDC
1006
Clock (year)
0
6Hz
1007
Clock (month, day)
100%
9999
9999
9999
100%

Inverter
capacity

0
1008
Clock (hour, minute)
9999
9999
9999
Running speed after
1013
emergency drive retry
0Hz
reset
Integral stop selection
0%
1015
at limited frequency
PTC thermistor
60Hz
1016
protection detection time
1018
Monitor with sign selection 0, 9999
100%
1020
Trace operation selection 0 to 4
0Hz
1021
Trace mode selection
1022
Sampling cycle
20%
Number of analog
1023
channels
60Hz
1024
Sampling auto start
1025
Trigger mode selection 0 to 4
100%
Setting
Initial
Pr.
range
value
Number of sampling
0 to 590Hz
0Hz
1026
before trigger
0%
Analog source selection
1027
(1ch)
0 to 590Hz
60Hz
Analog source selection
1028
(2ch)
100%
Analog source selection
1029
0 to 400%
0%
(3ch)
Analog source selection
0%
1030
(4ch)
0 to 400%
150%
Analog source selection
1031
(5ch)
100%
Analog source selection
1032
(6ch)
0 to 100%
0%
Analog source selection
1033
(7ch)
0 to 100%
0%
Analog source selection
1034
(8ch)
0 to 100%
100%
1035
Analog trigger channel 1 to 8
0 to 100%
100%
Analog trigger
1036
operation selection
0 to 400%
0%
1037
Analog trigger level
Digital source selection
20%
1038
(1ch)
0 to 400%
150%
Digital source selection
1039
(2ch)
100%
Digital source selection
1040
0 to 500.00,
(3ch)
9999
9999
Digital source selection
1041
(4ch)
0 to 300%
20%
Digital source selection
1042
0 to 500.00,
(5ch)
9999
9999
Digital source selection
1043
(6ch)
0 to 300%
100%
Digital source selection
1044
10
10


(7ch)
100
100


Digital source selection
1045
(8ch)
0, 1
1
1046
Digital trigger channel
58
Digital trigger operation
1047
selection
0 to 255, 9999 9999
1048
Parameter for manufacturer setting. Do not set.
0, 8009, 8109,
0
1049
USB host reset
9009, 9109
1106
Torque monitor filter
1, 2,10 to 13,
9999
20, 21, 9999
Running speed monitor
1107
filter
0
Excitation current
50 to 150%,
1108
9999
monitor filter
9999
Station number in
2000 to 2099
2000
1124
inverter-to-inverter link
101 to 131,
Number of inverters in
201 to 229,
1125
inverter-to-inverter link
301 to 331,
system
401 to 430,
501 to 531,
Pre-charge change
1132
601 to 630,
increment amount
101
701 to 731,
Second pre-charge
801 to 831,
1133
change increment
901 to 930,
amount
1001 to 1031,
1101 to 1130,
Second PID display
1136

1201 to 1231
bias coefficient
0 to 59, 100 to
Second PID display
1137

159, 200 to
bias analog value
259, 300 to
Second PID display gain
1138
359,

coefficient
400 to 459,
Second PID display
500 to 559,
1139

gain analog value
600 to 659,
700 to 759,
Second PID set point/
1140
800 to 859,
deviation input selection
900 to 959,
Second PID measured
1000 to 1059,
1141
value input selection
1100 to 1159,
0
1200 to 1259,
Second PID unit
1142
1300 to 1359,
selection
1400 to 1459,
1143
Second PID upper limit 0 to 100%, 9999 9999
1500 to 1559,
1600 to 1659,
1144
Second PID lower limit 0 to 100%, 9999 9999
1700 to 1759,
Second PID deviation
1800 to 1859,
1145
limit
1900 to 1959,
Second PID signal
2000 to 2059,
1146
operation selection
2100 to 2159,
2200 to 2259,
Second output
2300 to 2359
1147
interruption detection
time
0 to 590Hz
60Hz
Second output
1148
interruption detection
level
0 to 2, 10 to 12 0
Second output
1149
interruption cancel level
0 to 60s
0s
1150
to
User parameters 1 to 50 0 to 65535
9999
1199
0
PID gain tuning timeout
1211
0 to 2
0
time
0 to 9
2
Step manipulated
1212
amount
1 to 8
4
Step response
1213
0, 1
0
sampling cycle
0
Timeout time after the
1214
maximum slope
INVERTER FUNCTION SETTING
Parameter list
Setting
Initial
Name
range
value
0 to 100%
90%
201
202
1 to 3, 5 to 14,
203
17, 18, 20, 23,
24, 34, 40 to
204
42, 52 to 54,
61, 62, 64, 67,
68, 81 to 96,
205
98, 201 to 213,
230 to 232,
206
237, 238
207
208
1
0, 1
0
600 to 1400
1000
1
2
3
4
1 to 255
5
6
7
8
1 to 8
1
0, 1
0
0, 1
0
0 to 5s, 9999
9999
0 to 5s, 9999
9999
0 to 5s, 9999
9999
0 to 5, 9999
9999
2 to 6
2
0 to 100%,
9999
9999
0 to 100%,
9999
9999
0 to 500, 9999 9999
0 to 300%
20%
0 to 500, 9999 9999
0 to 300%
100%
1 to 5
2
1 to 5,
3
101 to 105
0 to 43, 9999
9999
0.0 to 100.0%,
9999
9999
0 to 7, 10 to 17 0
0 to 3600s,
1s
9999
0 to 590Hz
0Hz
900 to 1100% 1000%
0
1 to 9999s
100s
900 to 1100% 1000%
0.01 to 600s
1s
1 to 9999s
10s
19