Download Print this page

Sealey TA300 Instructions page 2

Automotive pen probe digital meter

Advertisement

Item
Description (Fig.1)
1.
"HOLD" button.
After "Hold" button is pressed, the present reading will be held in the display.
2.
"LIGHT" button.
To enable spotlight function, press "Light" button.
To disable, press the "Light" button again.
3.
"SELECT" button.
When meter is in the Vdc range press the "Select" button to change to
the Vac range, press "Select" again and the meter will return to the Vdc range..
When the meter is in the resistance range press the "Select" button to change to
to diode range. Press "Select" again, for continuity range. Press "Select"
again for capacitance range.
When the meter is in frequency range, press the "Select" button for
duty cycle.
4.
"POWER" button.
The "Power" button is used for switching the meter on.
Press "Power" again to turn the meter off.
5.
"FUNCTION" switch.
Use "Function" switch to select between Vac, Vdc, resistance,
capacitance, frequency, duty cycle, continuity test, audible continuity
and diode test.
6.
Test probe. (+Test Probe)
7.
Test lead.
(-Test Lead)
8.
Crocodile clip.
9.
Cigarette lighter adaptor.
3.
SPECIFICATION
Accuracy is specified for a period of one year after calibration and at 23 ± 5°C with relative humidity up to 75%.
Accuracy specifications take the form of:
± (% of Reading + number of least significant digits).
DC VOLTAGE
Range
400mV
4V
40V
400V
600V
Input impedance: 10Ω
RESISTANCE
Range
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
Overload protection: 250Vdc or rms ac
FREQUENCY
Range
9.999Hz
99.99Hz
999.9Hz
9.999kHz
99.99kHz
999.9kHz
10MHz
Input voltage range: 0.5 - 50 Vp-p
Range
Resolution
1mV
Resolution
Accuracy
0.1mV
1mV
± (0.8%+4)
10mV
100mV
1V
± (1%+4)
Resolution
Accuracy
0.1Ω
± (1.2%+2)
1Ω
10Ω
± (1%+2)
100Ω
1kΩ
± (1.2%+2)
10kΩ
± (1.5%+2)
Accuracy
± (1.5%+4)
DIODE
Open-circuit Voltage:
About 1.5V.
Forward voltage:
About 0.5 - 0.8V
Fig.1
8
4
3
7
AC VOLTAGE
Range
Resolution
4V
1mV
40V
10mV
400V
100mV
600V
1V
Input impedance: 10MΩ
Frequency response: 40 - 400\Hz
CAPACITANCE
Range
Resolution
4nF
1pF
40nF
10pF
400nF
100pF
4µF
1nF
40µF
1nF
100µF
100nF
Overload protection: 250Vdc or rms ac
DUTY CYCLE
Range
Resolution
0.1% - 99%
0.01%
Input voltage range: 0.5 - 50 Vp-p
CONTINUITY
If < 50Ω, the buzzer will sound
Note: When the resistance is between 50Ω and
120Ω, the buzzer may or may not sound. When
the resistance is more than 120Ω, the buzzer
will not sound.
6
9
Accuracy
± (0.8%+6)
± (1.2%+6)
Accuracy
± (25%+5)
± (10%+5)
Accuracy
± (2.5%+4)
TA300 - 1 - 310807
5
2
1

Advertisement

loading