External Electrical Connection - Airflow Adroit DV245 Series Instruction Manual

Hide thumbs Also See for Adroit DV245 Series:
Table of Contents

Advertisement

DV245
POWER SUPPLY
Maximum
≤6W
transmitter
Adroit Digital
1W
Controller
Adroit RH%
0.3 W
transmitter
Adroit CO
1.2 W
2
transmitter
Voltage
24 VDC
transmitter
External temperature
transmitter NTC 4K7
2x0,5
2x0,5
Digital input 1
Digital input 2
8 different
8 different
functions
functions
Ethernet connection
on top of the unit
CAT
RJ45 female
MB_A
External Modbus A signal
MB_B
External Modbus B signal
+24V
+24V direct current voltage (DC)
GND
Digital and analog ground potential
RS_A
Local hardware Modbus A signal
RS_B
Local hardware Modbus B signal
NTC
External temperature sensor connector
Adroit
REMOTE
RH%
MONITORING
Modbus RTU
2x2x0,5+0,5
Adroit
CO
2
2x2x0,5+0,5
2x2x0,5+0,5
2x0,5
VENTILATION UNIT INTERNAL
ELECTRICAL CONNECTION

EXTERNAL ELECTRICAL CONNECTION

2x0,5
2x0,5
D/I1
Digital input 1
D/I2
Digital input 2
11V1
11.1 V operating voltage
AN/I
AN/I = Analog input 0-10VDC
RM/I
24V relay input
RM/O
24V relay output
38
7028350
2014-08-29 JS
Adroit
Digital
Controller
2x2x0,5+0,5
Adroit
Digital
Controller
2x2x0,5+0,5
Analog input
two different
functions
Potential-free contact
data 24VDC can be
programmed to display
information such as
errors or the status of
the cell bypass
Mains supply cable
3x1,5S

Advertisement

Table of Contents
loading

This manual is also suitable for:

Adroit dv245 rAdroit dv245 l9000058290000583

Table of Contents