Installation Instructions; Installation Diagram; Site Instructions - Emerson Quiet Kool 21 SEER Series Installation Manual

Wall-mounted type
Hide thumbs Also See for 21 SEER Series:
Table of Contents

Advertisement

Available languages

Available languages

Installation Instructions

Installation diagram

Distance from wall
should be over 50mm/2in
Distance from the obstacle
should be over 3.0m/10ft.
Distance from floor
over 2.4m/8ft.
Above figure is only a simple presentation of the unit, it may not match the external appearance of the unit you purchased.
Installation must be performed in accordance with the national wiring standards by authorized personnel only.

Site Instructions

Site for Installing Indoor Unit
1. Where there is no obstacle near the air outlet and air can be
easily blown to every corner.
2. Where piping and wall hole can be easily arranged.
3. Keep the required space from the unit to the ceiling and wall
according to the installation diagram on previous page.
4. Where the air filter can be easily removed.
5. Keep the unit and remote controller 1m(3.28ft) or more apart
from television, radio etc.
6. Keep as far as possible from fluorescent lamps.
7. Do not put anything near the air inlet to obstruct it from air
absorption.
8. Install on a wall that is strong enough to bear the weight of t
he unit.
9. Install in a place that will not increase operation noise and
vibration.
10. Keep away from direct sunlight and heating sources. Do not place
flammable materials or combustion apparatuses on top of the unit.
Installation of outdoor unit refers to the outdoor unit installation manual.
Distance from ceiling
should be over
200 mm/7.9in
should be
Indoor unit A
5
Distance from the wall
should be over 50mm/2in
Indoor unit
Pipe length is
20 meters
(65.4ft) Max.
Outdoor unit
Indoor unit is higher than outdoor unit