Emerson Quiet Kool 19 SEER Series Owner's Manual

Emerson Quiet Kool 19 SEER Series Owner's Manual

Wall-mounted type

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Emerson Quiet Kool 19 SEER Series

  • Page 3: Table Of Contents

    CONTENTS SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER ......1 ......................4 NAMES OF THE PARTS INDOOR UNIT DISPLAY ......................5 EMERGENCY FUNCTION & AUTO-RESTART FUNCTION ..........6 REMOTE CONTROL .......................7 OPERATING INSTRUCTIONS ....................11 PROTECTION .........................18 INSTALLATION MANUAL ....................20 MAINTENANCE ........................27 ......................28 TROUBLESHOOTING...
  • Page 4: Safety Rules And Recommendations For The Installer

    SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER Do not install the appliance at a distance of Read this guide before installing and using the less than 20” from inflammable substances appliance. (alcohol, etc.) or from pressurised containers (e.g. spray cans). During the installation of the indoor and outd- oor units the access to the working area should If the appliance is used in areas without the...
  • Page 5 SAFETY RULES AND RECOMMENDATIONS FOR THE USER Do not try to install the air condition alone; Never remain directly exposed to the flow of always contact specialized technical personnel. cold air for a long time. The direct and prolo- nged exposition to cold air could be dangero- Cleaning and maintenance must be carried out us for your health .Particular care should be by specialized technical personnel.
  • Page 6 SAFETY RULES AND PROHIBITIONS Do not bend, tug or compress the power cord Do not climb onto or place any heavy or hot since this could damage it. Electrical shocks or objects on top of the appliance. ire are be caused by a damaged power cord.
  • Page 7: Names Of The Parts

    NAMES OF THE PARTS INDOOR UNIT Description Front panel Air filter Optional filter (if installed) LED Display Signal receiver Terminal block cover Ionizer generator (if installed) Deflectors Emergency button Indoor unit rating label ( Stick position optional Airflow direction flaps Remote control OUTDOOR UNIT No.
  • Page 8: Indoor Unit Display

    INDOOR UNIT DISPLAY Function The symbol appears when power on. POWER SLEEP mode SLEEP (1) Lights up during Timer operation when the air conditioner is operational. Temperature display (if present) (2)Displays the malfunction code when fault /Error code occurs. TIMER Lights up during Timer operation.
  • Page 9: Emergency Function & Auto-Restart Function

    EMERGENCY FUNCTION & AUTO-RESTART FUNCTION If the remote controller fails to work or maintenance necessary, proceed as following: front panel Open and lift the front panel up to an angle to reach the emergency button. For heating model, press the emergency button at first time, the unit will operate in COOL mode.
  • Page 10: Remote Control

    REMOTE CONTROL ( NOTE: SEE ILLUSTRATION ON PAGE 8 ) Button Function To turn on/off the air conditioner . To decrease temperature, time setting or choose the function. To increase temperature, time setting or choose the function. To select the mode of operation(AUTO, COOL, DRY, FAN, HEAT). MODE To activate/deactivate the ECO function .
  • Page 11 REMOTE CONTROL The display and some functions of the remote control may vary according to the model. The shape and position of buttons and indicators may vary according to the model, but their function is the same. The unit confirms the correct reception of each button with a beep.
  • Page 12 REMOTE CONTROL Remote control DISPLAY Meaning of symbols on the liquid crystal display Symbols Meaning Battery indicator Auto Mode function indicator Cooling Mode indicator Dry Mode indicator Fan only Mode indicator Heating Mode indicator ECO Mode indicator Timer indicator Temperature indicator Fan speed indicator: Auto/low/mid/high Mute function indicator SUPER function indicator...
  • Page 13 REMOTE CONTROL Replacement of Batteries Remove the battery cover plate from the rear of the remote control, by sliding it in the direction of the arrow. nstall the batteries according the direction (+and -)shown on the Remote Control. Reinstall the battery cover by sliding it into place. Use 2 pieces LRO3 AAA (1.5V) batteries.
  • Page 14: Operating Instructions

    OPERATING INSTRUCTIONS SWING function 1. Press the button SWING to activate the louver, (1) Press to activate the horizontal flaps to swing from up to down. Press again to stop the swing movement at the current angle. (2) Press to active the vertical deflectors to swing from left to right.
  • Page 15 OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS COOLING MODE The cooling function allows the air condit- COOL ioner to cool the room and at the same time reduces Air humidity. To activate the cooling function ( COOL ) , press the MODE button until the symbol appears on the display.
  • Page 16 OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS DRY MODE This function reduces the humidity of the air to make the room more comfortable. To set the DRY mode , Press MODE until appears in the display. An automatic function of pre-setting is activated. FAN MODE(Not FAN button) Fan mode, air ventilation only.
  • Page 17 OPERATING INSTRUCTIONS DISPLAY function (Indoor display) Switch ON/OFF the LED display on DISPLAY panel. Press DISPLAY button to switch off the LED display on the panel. Press again to switch on the LED display. SLEEP function Pre-setting automatic operating program. SLEEP Press SLEEP button to activate the SLEEP function, appears on the display.
  • Page 18 OPERATING INSTRUCTIONS ECO function In this mode the appliance automatically sets the operation to save energy. Press the ECO button, the appears on the display, and the appliance will run in ECO mode. Press again to cancel it.. NOTE: The ECO function is available in both COOLING and HEATING modes.
  • Page 19 OPERATING INSTRUCTIONS TIMER function ---- TIMER ON To automatic switch on the appliance. TIMER When the unit is switch-off, you can set the TIMER ON. To set the time of automatic switch-on, as below: 1. Confirm the appliance is OFF. And press the TIMER button at first time to set the needed mode and fan speed, the will appear on the display.
  • Page 20 OPERATING INSTRUCTIONS I FEEL function (Optional) I FEEL Press I FEEL button to active the function, the will appear on the remote display. Do it again to deactivate this function. This function enables the remote control to measure the temperature at its current location, and send this signal to the air conditioner to optimize the temperature around you and ensure the comfort.
  • Page 21: Protection

    PROTECTION The protective device may stop the appliance, when the ambient temperature is off range as listed below. Inverter air conditioner: MODE Cooling operating Heating operating Drying operating Temperature 17 ~32 0 ~30 17 ~32 Room Temperature 63 ~89 32 ~86 63 ~89 -15 ~53 -25 ~30...
  • Page 22 INSTALLATION---Selecting the Installation Place INDOOR UNIT Mounting plate Install the indoor unit level on a strong wall that is not 6 or subject to vibrations. 150mm 6 or 6 or The inlet and outlet ports should not be obstructed: the 150mm 150mm air should be able to blow all over the room.
  • Page 23: Installation Manual

    INSTALLATION MANUAL---Installation of the Indoor unit Before starting installation, decide on the position of the indoor and outdoor units, taking into account the minim- um space required around the units. Install the indoor unit in the room to be air conditioned avoiding in corridors or communal areas.
  • Page 24 INSTALLATION MANUAL---Installation of the Indoor unit Refrigerant piping connection The piping can be ran in 3 directions (indicated by numbers in the pictures). When the piping is ran in direction 1or3, cut a notch along the groove on the side of the indoor unit with a cutter.
  • Page 25 INSTALLATION MANUAL---Installation of the Indoor unit INSTALLATION OF THE INDOOR UNIT After having connected the pipe according to the instruc- Covered by vinyl tape tions, install the connection cables. Now install the drain refrigerant insulation pipe. After connection,lag the pipe, cables and drain pipe pipe sleeve with the insulating material.
  • Page 26 INSTALLATION MANUAL---Installation of the outdoor unit ELECTRICAL CONNECTIONS wiring diagram on the back of the cover 1. Remove the handle on the right side plate of outdoor unit. 2. Connect the power connection cord to the terminal board. Wiring should fit that of indoor unit. 3.
  • Page 27 INSTALLATION MANUAL---Installation of the outdoor unit BLEEDING INSTALLATION MANUAL---operation test Wrap applying correctly? correctly? correctly? correctly?
  • Page 28 INSTALLATION MANUAL---Information for the installer North American INVERTER TYPE MODEL capacity (Btu/h) Liquid pipe diameter ( 6.35) ( 6.35) ( 6.35) ( 6.35) ( 6.35) Gas pipe diameter ( 9.52) ( 9.52) ( 9.52) ( 12.7) ( 15.88) Lengh of pipe with standard charge 7.5m / 25ft 7.5m / 25ft 7.5m / 25ft...
  • Page 29 INSTALLATION MANUAL---Information for the installer WIRING DIAGRAM For different models, the wiring diagram may be different. Please refer to the wiring diagrams affixed to the indoor unit and outdoor unit respectively. On the indoor unit, the wiring diagram is l ocated under the front panel;...
  • Page 30: Maintenance

    MAINTENANCE Periodic maintenance is essential for keeping your air conditioner efficient. Before carrying out any maintenance, t urn the power supply off . INDOOR UNIT ANTIDUST FILTERS 1. Open the front panel (following the direction of the arrow). 2. Keeping the front panel raised with one hand, take out the air filter with the other hand.
  • Page 31: Troubleshooting

    TROUBLESHOOTING MALFUNCTION POSSIBLE CAUSES Power failure/plug pulled out. Damaged indoor/outdoor unit fan motor. Faulty compressor thermomagnetic circuit breaker. Faulty protective device or fuses. The appliance does not Loose connections or plug pulled out. operate It sometimes stops operating to protect the appliance. Voltage higher or lower than the voltage range.
  • Page 32 For any questions or Technical Support, Please Call Customer Service: 1-844-801-8880...

Table of Contents