Mounting Procedure - Add a ground lug to point A and point D as in the figure
shown below. Take the 200mm wires and route them through the holes labeled
E and F in the main pcb as in the diagram below. The holes are located next to
the IC301 heatsink. Solder the 200mm wires to the heatsink solder connection
located nearest to the routed wire hole. The other end of the 200mm wires are to
be soldered to the CRT ground wire as shown below.
Disclaimer: This information is provided "as is" without warranty of any kind
either expressed or implied, including, but not limited to, the implied
warranties of merchantability and fitness for a particular purpose.
REV 9-1