Download Print this page
Zircon SL-AC Manual

Zircon SL-AC Manual

Stud finder with ac wirewarning and spotlite pointing system

Advertisement

Quick Links

StudSensor
Pro SL-AC Stud Finder
with AC WireWarning
SpotLite
®
The Zircon StudSensor
Pro SL-AC
detects wood and metal studs
and joists in walls, floors, and
ceilings. It features two scanning
modes, recessed LEDs, a durable
high-impact case, and the
patented SpotLite
®
Pointing System.
It also has WireWarning
to continuously detect hot
AC voltage in both modes.
INSTALLING THE BATTERY
Squeeze sides of
1
clip to help
release clip end.
Slide 9-V battery
2
into compartment,
terminal side first,
matching (+) and (–)
terminals from battery to case.
Replace the clip.
3
Battery will last
approximately two years
under normal conditions.
CALIBRATION AND SCANNING IN
STUD SCAN OR DEEPSCAN
®
MODES
Note: Unit calibrates on each use.
Use Stud Scan Mode for depths to about
(19 mm) and DeepScan for depths up to
1
1
in. (38 mm) or double layers.
2
Note: Keep unit flat against wall. Do not lift or tilt
unit during calibration or scanning.
Slide the Mode Selector
4
switch to the desired
scanning mode. The mode can
be selected with the unit on
or off.
With StudSensor Pro SL-AC
5
turned off, position the unit
flat against the wall.
Without moving unit, squeeze
6
and hold On/Off button.
TruCal
®
LED should be lit.
Continue to hold
7
in the On/Off
button then slowly slide
unit horizontally across
the wall, right or left.
As you begin to approach a stud, the red LEDs
8
will light successively, from bottom to top.
and
Pointing System
SpotLite
Stud Edge Groove
AC WireWarning
StudScan
STUD SCAN
DEEPSCAN
®
Mode LED
On/Off Button
When the top green
9
LED is lit, a steady
tone sounds, and the
SpotLite
®
shines, you
have located the edge of
the stud. Mark this spot.
Continue scanning
10
beyond marked
spot until green LED goes
out. Slide unit in reverse
direction to locate other
edge of stud.
3
in.
4
Mark this second
11
spot. Middle of stud
is centered between the
two marks.
CONTINUOUS AC VOLTAGE
DETECTION (WireWarning
The StudSensor Pro
12
SL-AC detects from
90 to 250 V at 50 to 60 Hz
AC in a hot electrical wire.
The voltage detection
feature works continuously
in both Stud Scan and
DeepScan modes. When
sensing voltage, the small
AC light comes on.
Caution: The StudSensor Pro SL-AC will not
detect hot wires inside metal pipe or conduit,
behind metallic wall covering, or behind some
plywood or other dense materials. Use extra
caution in these situations. Always turn the
power off when nailing, cutting, or drilling
near electrical wires.
OPERATING CAUTIONS
Depending on the proximity of electrical wiring
13
or pipes to the wall surface, the scanner may
detect them in the same manner as studs. Caution
should always be used when nailing, cutting, or
drilling in walls, floors, and ceilings that may contain
these items.
To avoid surprises, remember that studs or joists are
normally spaced 16 in. (406 mm) or 24 in. (610 mm)
apart and are 1
1
in. (38 mm) in width. Anything
2
closer together or a different width may not be a
stud, joist, or firebreak. Always turn off the power
when working near electrical wires.
WORKING WITH DIFFERENT MATERIALS
StudSensor Pro SL-AC is for use on dry, interior walls only. Although StudSensor Pro
SL-AC can scan through up to
1
1
in. (38 mm) of common construction materials in DeepScan mode, three pri-
2
mary factors can affect sensing depth: thickness, density, and moisture content.
StudSensor Pro SL-AC can scan effectively through most sheet materials, including:
• Bare wood flooring (in DeepScan mode)
• Linoleum on wood base
®
Pointing System
• Gypsum drywall over plywood sheathing
• Wallpapered walls (if dry)
• Textured ceilings if uniform thickness (Place a thin piece of cardboard on ceiling
and scan through it to avoid damage
to texturing.)
StudSensor Pro SL-AC is not designed to scan materials with inconsistent density
such as:
• Ceramic floor tile
TruCal
®
• Carpeting and padding
LED
• Wallpaper with metallic fibers
Stud DeepScan
®
• Freshly painted walls that are still damp (must dry at least
Mode LED
a week)
• Lath and plaster walls
Mode Switch
• Foil covered insulation board
FCC Part 15 Class B Registration Warning
This equipment has been tested and found to comply with the limits for a Class B digital device, pur-
suant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when the
equipment is operated in a residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no guar-
antee that
interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be deter-
mined by turning the equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
(1) Reorient or relocate the receiving antenna.
(2) Increase the separation between the equipment and receiver.
(3) Connect the equipment into an outlet on a circuit,
different from that which the receiver is connected
(if applicable).
(4) Consult the dealer or an experienced radio/TV
technician for help.
HELPFUL HINTS
Situation
Lights start flashing and
unit starts beeping.
Center green LED doesn't
light in Stud Scan mode.
)
The green TruCal LED
lights but, when scan-
ning, unit doesn't do
anything else.
All three red LEDs and
green LED light at the
same time and unit
beeps continuously.
Working in DeepScan
mode and can't detect
studs.
Detects other objects
besides studs.
You suspect electrical
wires, but do not
detect any.
Area of voltage detection
is too large.
Questions? Check our Web site at www.zircon.com and click "Support."
Probable Causes
• Turn unit off, move over a few inches, press On/Off button,
• Scan began on dense part of
wall or over a stud.
and start again.
• Unit not flat against wall.
• On rough surfaces, place piece of paper on wall, scanning
through it to help slide unit more smoothly.
• Unit tilted or lifted during scan.
(All these factors affect proper
• Keep hand at least 6 in.(152 mm) from StudSensor
calibration.)
Pro SL-AC while you calibrate and scan. Hold unit with
thumb and index finger no higher than handgrips. Be
careful not to move your fingers after calibration.
• Always hold unit parallel to and move perpendicular to
object you're trying to locate.
• Wall is particularly thick or
• Interpret red LED closest to center as stud edge.
dense.
• Switch to DeepScan to locate the stud.
• Unit may not be flat against
• Hold unit so two Velcro
contact with wall.
the wall.
• If it is in the DeepScan mode
• Recalibrate unit in a different place and rescan area.
(the DeepScan LED is lit), you
may have calibrated over a stud.
• Scanning surface is too dense
• If you are using unit on a recently taped, painted, or
or too wet for unit to operate.
wallpapered wall, allow time to dry and try again.
• You may have calibrated over
• Move StudSensor Pro SL-AC over a few inches
a stud. (The error condition is
and recalibrate.
disabled in DeepScan mode
because it is twice as sensitive
as Stud Scan.)
• Hold unit so two Velcro
• You may be holding the unit
like a TV remote, aiming it at
contact with wall.
the wall.
• Electrical wiring and metal or
• Remember that studs or joists are normally spaced 16 in.
plastic pipes may be near or
(406 mm) or 24 in. (610 mm) apart and are 1
touching back surface of wall.
(38 mm) wide.
• Always turn off power when cutting, nailing, or drilling
near electrical wires.
• Wires may be shielded behind
• See above solution.
metallic wall coverings,
• Use extra caution if the area has plywood, thick wood
plywood shearwall or other
backing behind drywall, or thicker-than-normal walls.
dense material, or in conduit;
• If a switch controls an outlet, make sure it is ON for
StudSensor Pro SL-AC may not
detection, but turned off when working near electrical wires.
be able to find them.
• The wires may not be hot.
• Wires may be too deep to sense.
• To narrow detection, turn unit off and on again at the edge
• Static charge may develop on
drywall, spreading voltage
of where wire was detected and scan again.
detection as much as 12 in.
(305 mm) from each side of
an actual electrical wire.
Solutions
strips on the back make
strips on the back make
1
in.
2

Advertisement

loading

This manual is also suitable for:

Studsensor pro sl-ac