Middle Atlantic Products Protection Series Instruction Sheet

Middle Atlantic Products Protection Series Instruction Sheet

Power distribution with series circuit protection

Advertisement

POWER DISTRIBUTION WITH SERIES
THANK YOU
Thank you for purchasing this Series Protection™ Product.

PRODUCT FEATURES

- Non-sacrificial surge technology protects equipment without compromising system ground.
- No MOVs or other degrading parts
- Voltage protection automatically powers outlets off during over/under voltage conditions and
automatically restores power when voltage returns to normal
- Thermal circuit breaker overload protection
- Advanced EMI / RFI filtering
- Automatic self-test circuit with front panel indicators
- Universal mounting brackets
Instruction Sheet
Series Protection
CIRCUIT PROTECTION
U.S. Patent No. 8,947,844
(PD-915R-SP Shown)
I-00537
Rev D

Advertisement

Table of Contents
loading

Summary of Contents for Middle Atlantic Products Protection Series

  • Page 1: Product Features

    Instruction Sheet Series Protection ™ POWER DISTRIBUTION WITH SERIES CIRCUIT PROTECTION U.S. Patent No. 8,947,844 (PD-915R-SP Shown) THANK YOU Thank you for purchasing this Series Protection™ Product. PRODUCT FEATURES - Non-sacrificial surge technology protects equipment without compromising system ground. - No MOVs or other degrading parts - Voltage protection automatically powers outlets off during over/under voltage conditions and automatically restores power when voltage returns to normal - Thermal circuit breaker overload protection...
  • Page 3: Before You Begin

    IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS! DANGER HAZARDOUS VOLTAGE/DANGER HAUTE CONSERVER CES INSTRUCTIONS! TENSION The lightning flash with the arrowhead symbol, within an • Contains switched receptacle(s). To reduce risk of shock , disconnect the equilateral triangle is intended to alert the user to the device from the power source before servicing any connected presence of uninsulated dangerous voltage within the equipment...
  • Page 4: Regulatory Compliance

    REGULATORY COMPLIANCE The product meets the requirements of the following standards: • UL 1283 and UL 1449, 3rd Ed. • CSA C22.2 No.8-M1986, R2000 Federal Communications Commission (FCC) Compliance Statement NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
  • Page 5: Table Of Contents

    TABLE OF CONTENTS Product Features Page 1 Before You Begin Page 3 Important Safety Instructions Page 3 Regulatory Compliance Page 4 Introduction Page 5 Connections, Controls and Indicators Page 6 Models Page 7 Installation Pages 8 - 9 Specifications Page 10 Warranty Page 11 INTRODUCTION...
  • Page 6: Connections, Controls And Indicators

    CONNECTIONS, CONTROLS AND INDICATORS PD-915R-SP POWER PD-915R-SP PD-920R-SP POWER RESET PD-920R-SP POWER 20 AMP POWER CENTER OVERVOLTAGE WHEN LIT 15 AMP POWER CENTER POWER OVERVOLTAGE RESET WHEN LIT UNDERVOLTAGE PROTECTED WHEN LIT WHEN LIT PROTECTED UNDERVOLTAGE WHEN LIT WHEN LIT 120V - TOTAL 15A - 60Hz PD-415R-SP SWITCHED...
  • Page 7: Models

    CONNECTIONS, CONTROLS AND INDICATORS (CONTINUED) DESCRIPTION FRONT CONVENIENCE POWER OUTLET (REFER TO MODELS FOR AMPERAGE RATING) POWER LED: Illuminates green to indicate operational status. OVERVOLTAGE / UNDERVOLTAGE LEDS Overvoltage LED indicates red when overvoltage condition is present. Undervoltage LED indicates red when undervoltage condition is present. 9FT POWER CORD (EXCEPT PD-HW15-SP) POWER SWITCH (INTEGRATED CIRCUIT BREAKER INCLUDED ON PD-915R-SP and PD-415R-SP ONLY)
  • Page 8: Installation Pages

    INSTALLATION NOTE: Any attachment-plug receptacles in the vicinity of Series Protection™ products are to be of a grounding type, and ground conductors serving these receptacles are to be connected to earth ground at the service entrance or other acceptable building earth ground. Rack Mount Screws (4) Rack Mount Screws (4) 1) PD-915R-SP / PD-920R-SP MOUNTED IN A STANDARD 19”...
  • Page 9 INSTALLATION (CONTINUED) 10-32 Sliding Nuts (2) Rack Mount Screws (4) Threaded Clips (2) Rack Mount Screws (2) Rack Mount Screws (2) Rack Mount Screws (2) PD-HW15-SP MOUNTED PD-415R-SP / PD-420R-SP MOUNTED IN A STANDARD 19” RACK TO VISIONFRAME™ MONITOR WALL PD-HW15-SP COVER REMOVAL AND WIRING Must be installed by Qualified Electrical Personnel (Licensed Electrical Contractor) 1) Remove two (2) cover screws to access wiring.
  • Page 10: Specifications

    SPECIFICATIONS SPECIFICATION DETAILS Load rating @ 120 VAC PD-915-SP, PD-415R-SP, PD-HW15-SP 15 Amp RMS load @ 120 VAC PD-920-SP, PD-420R-SP 20 Amp RMS load @ 120 VAC Operating Voltage Range 90-150V Power Requirement (no load) 5 watts Maximum Ambient Temperature 35ºC Voltage Protection Rating 330V...
  • Page 11: Warranty

    WARRANTY Middle Atlantic Products (the "Company") warrants the Series Protection Power Distribution with Series Circuit Protection to be free from defects in material or workmanship under normal use and conditions for a period of (12) twelve years from date of shipment by the Company.

This manual is also suitable for:

Pd-915r-spPd-920r-spPd-415r-spPd-420r-spPd-hw15-sp

Table of Contents