10 ft. 15 ft. 20 ft. 25 ft. 62041 66PSI SAFETY INSTRUCTIONS 1.Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion or fire, resulting in property damage, serious personal injury, and/or death.
20.This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free service for a long time when properly installed, maintained, and used. However, inadequate electrical power to the pump, dirt, or debris may cause the pump to fail. Please carefully read the manual and follow the instructions regarding common pump problems and remedies. 21.
TOOLS REQUIRED Flathead Phillips Hacksaw Pipe wrench Screwdriver Screwdriver Tape Measure Safety goggles PVC glue Thread Tape MATERIALS REQUIRED (NOT INCLUDED) Discharge tee Pipe Threaded adapter Elbow Ball valve Check valve Union SPECIFICATIONS POWER SUPPLY 115V,60HZ,20Amp circuit LIQUID TEMP. RANGE 32°F to 77°F (0°- 25°C) DISCHARGE 1in.NPT...
Page 5
READ STEP 6 COMPLETELY BEFORE STARTING WORK. You must remove a length of pipe from the main water supply line to allow installation of tees for the Pump. The locations of the cuts must take into consideration the size of the tees being used, the length of the threads in threaded joints or the overlap in glued or soldered joints, etc..
Page 6
12. Before continuing with the installation, see the manual sections titled Electrical Connections, Automatic Pressure Controller, Normal Operation, and When Does The Pump Stop Operating for detailed information on how the system functions. 13. At this point, you can plug in the pump for the first time. When you plug in the power cord, the pump will start and run for a few seconds.
OPERATION WARNING: Risk of burns. NEVER run the pump dry. Running the pump without water may cause pump to overheat and cause burns to persons handling the pump. It may also damage the impeller and may damage the seal, causing leaking or flooding, and will void the warranty.
TROUBLESHOOTING Problem Possible Cause Corrective Action Motor will not run. 1. Fuse is blown or circuit breaker tripped. 1. DISCONNECT POWER; Replace fuse or 2. Power cord not plugged in. reset circuit breaker. 2. Plug into 115 Volt grounded outlet. Motor runs hot 1.
(the “Warranty Period”). During the Warranty Period, AQUAPRO will repair or replace at no cost to you, to correct any such defect in products founds upon examination by AQUAPRO to be defective in materials or workmanship.
Page 10
Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475...
Need help?
Do you have a question about the 62041 and is the answer not in the manual?
Questions and answers