Ada MP-1 Owner's Manual

Midi programmable tube preamp
Hide thumbs Also See for MP-1:

Advertisement

$'$ 6,*1$/ 352&(66256 ,1&
' (GJHZDWHU 'ULYH 2DNODQG &$ 
3KRQH   7HOH[  )$;  
$'$ 6,*1$/ 352&(66256
Ada-mp1.pub
Saturday, 28 August 1999 23:14
page 1
Black

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MP-1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ada MP-1

  • Page 1 $'$ 6,*1$/ 352&(66256 ,1& ' (GJHZDWHU 'ULYH 2DNODQG &$  3KRQH   7HOH[  )$;   $'$ 6,*1$/ 352&(66256 Ada-mp1.pub Saturday, 28 August 1999 23:14 page 1 Black...
  • Page 2: Table Of Contents

    DISPLAY VALUE DISPLAY VALUE SPECIFICATIONS MIDI SPECIFICATIONS SOFTWARE UPDATES RETURNING UNITS FOR SERVICE WARRANTY OPTIONAL EXTENDED WARRANTY TUBE REPLACEMENT 10.0 SYSTEM EXCLUSIVE MESSAGES 10.1 SYSTEM EXCLUSIVE MAP 10.2 SYSTEM EXCLUSIVE PARAMETER VALUES Ada-mp1.pub Saturday, 28 August 1999 23:14 page 2 Black...
  • Page 3: Quick Set-Up Guide

    10.1 SYSTEM EXCLUSIVE MAP 1.1 QUICK SET-UP GUIDE Note: The MP-1 is a preamp and must be connected to a power amp in order to play through loudspeakers. HEX ADDRESS 1 BYTE EACH Overdrive 2 INITIAL PREPARATION: Connect guitar to front panel input jack.
  • Page 4: Features

    Programmable compression level in Solid State mode. √ Received MIDI program numbers re-assignable SET PARAMETERS RESPONSE (mappable) to any MP-1 memory number. √ MIDI In, Out and Thru. <F0> SYSEX √ Selectable MIDI channel including ALL channels (OMNI) and NO channels (OFF).
  • Page 5 MIDI program number. DEVICE REASSIGN RESPONSE Selects the internal memory number on the <F0> SYSEX MP-1 that is assigned to the external MIDI <0D> ADA Identifier program number. When the LED is lit, the <cc> Old channel number display reads the internal memory number.
  • Page 6: Rear Panel

    ADA. This warranty remains MIDI IN jack, and do not connect an AC valid only if repairs are performed by ADA, and provided that the serial adaptor to the MC-1’s rear panel power jack.
  • Page 7: Initial Set-Up

    Thereafter, updates are $50 each. You can send your unit to Jack on the MP-1 to the MC-1 with the MIDI CABLE. You can use a ADA for installation or we can send you the EPROM. Always refer to qualified standard 5-pin MIDI cable and plug the AC ADAPTOR into the service personnel for installation.
  • Page 8: Editing And Storing Programs

    Press the EDIT button when you are through examining the COMPRESSED 10.0 S.S. CHORUS parameter values. The EDIT LED will turn off, and you will be MILD GRIND CLEAN returned to Program 1. COMPRESSED S.S. RHYTHM Ada-mp1.pub Saturday, 28 August 1999 23:14 page 8 Black...
  • Page 9: Using The Clip Led's

    The level control is configured to insure that you ADAPTOR is connected to a jack on the rear of the MP-1 labeled 9V have the same overall signal level whether the effects loop is in or out, AC/DC).
  • Page 10: Load Preset Programs

    “map” the reception of program 11 to memory 22 or any memory Check for distortion and excess noise. If your effect is clipping, turn location from 1 thru 128 in the MP-1. This gives you the potential of your EFFECTS LOOP LEVEL control counterclockwise.
  • Page 11 When the EDIT button is toggled on, you have access to the parameters in the working number or re- MP-1’s gain and tone controls ( gray area ). The MP-1 has a unique register are set to default enter parameter VOICING control which allows you to create programs using ultra-high- values.
  • Page 12: Specifications

    If no problem noise 12AX7 / 7025 tubes. exists, the DIAGNOSTIC operation is completed within eight seconds. Your MP-1 is now ready for operation. ( If a problem does MIDI Specification: 1.0 Rev 3.3;...
  • Page 13: Returning Units For Service

    Otherwise, send a copy of your original purchase invoice for proof of INPUT, 30K Ω Warranty coverage. If the unit is not under Warranty, ADA will bill you for the servicing and return shipping charges. We require payment in advance or RING, NEG cash on delivery ( COD ) for these charges.
  • Page 14 Other test numbers are device specific. • No response is sent by the device. EDIT Place the MP-1 into the Edit mode. The display reads “Edit” until a parameter is selected. Display REPORT DIAGNOSTIC STATUS then shows the value of the selected parameter.
  • Page 15 System Exclusive Message ID (SYSEX) WARNING: To prevent fire or shock hazard, do not expose this appliance to rain or moisture. Locate the MP-1 out of the direct rays <0D> ADA Identifier of the sun. Avoid locations subject to vibration and execessive dust, <cc>...
  • Page 16 STORE YOUR TONE: NOTES ON ADA SYSTEM EXCLUSIVE MESSAGES To store the new values that you have set, press STORE button. All messages include a 7 bit 2’s complement checksum taken over Select the location (Memory numbers 1-128) for storing your all of the data bytes (doesn’t include the SYSEX, EOX, or checksum...
  • Page 17 To properly set up and familiarize yourself with the MP-1, read and follw these operating instructions completely. If you can’t wait, and want to jump right into the MP-1, go to Section 1.1 QUICK SETUP. We hope that the unlimited tonal possibilities and unmatched technological capabilities of your MP-1 will inspire you to great things.

Table of Contents