12. Install cover (14) on body (3) with four screws (13).
Torque the screws to the value noted in parts drawing.
Refer to Table 1.
13. Install plugs (18) and ''O'' rings (19) into cover (7).
14 For DG3V8 models, install crossover plate (2) on body (3)
with four screws (1). Torque screws to value noted in
parts drawing. Refer to Table 1.
M. High/Standard Performance Pilot Valve
Assembly
(Refer to Figure 19)
1. Install ''O'' rings (25) on plugs (24). Lubricate plug
threads and install into body (10). Install remaining ''O''
rings (25) into body (10). Torque plugs to the value
shown in parts drawing. Refer to Table 1.
2. Lubricate pilot spool (22), then carefully install spool into
the body (10).
If pilot valve is equipped with two solenoids, repeat steps
3 through 7.
Note
3. Assemble washer (19) or (20) on end of spool (22) with
sharp break edge toward outside of body.
4. Install spring (18), push pin (17) and ''O'' ring (15) into
body (10).
5. Install ''O'' ring (16) on core tube S/A (21) and install core
tube S/A into body (10).
6. Install ''O'' ring (13) on core tube S/A (20).
7. Install coil (14) on body (10) and secure to core tube S/A
(20) with knob (12).
8. Install gasket (6) and terminal box (5) on body (10) and
secure with ground screw (11) and two screws (9).
9. Install strap (8) on terminal box (5) with two screws (7).
10. Install gasket (4), cover (3) and nameplate (2) on
terminal box (5) with four screws (1).