LIFEPLUS MOD3

Equalize Duration

Sets the equalization time from 00:01 to 23:59. (hh:mm)
erord

Start Charge Configuration

Charge Delay

Charge Delay Type:
-
OFF (no delay)
-
Charge Delay Time of Day
-
Time After Battery Connect
Charge Delay On Days: Selects day or days of the week to delay charge. One or more days may be
selected, or none.
Charge Delay Time of Day: Charge will not start until the time of day stored in VALUE (24 Hour format) is
reached.
Delay Time After Battery Connection: Start of charge is delayed by the amount of time stored in
VALUE (0 to 24 Hours).

Charge Blockout

Block out Days: Selects day or days of the week to block out charge. One or more days may be selected,
or none.
Block Out Start Time: Sets block out start time.
Block Out End Time: Sets block out end time.
Conditional Charge %
Set conditional charge %. The charger will only charge if the battery has reached the limit of depth of
discharge (DoD) of more than x%. For example if the user wants to charge the battery only if it is discharged
more than 30%, the parameter 30 has to be entered in the conditional charge. The 0 value disables the
function.

Opportunity Daily Charge

Start Daily Charge Time: Sets daily charge start time.
End Daily Charge Time: Sets daily charge end time.
erord

Post Charge Configuration

Cool Down ON/OFF

Turns the cool down ON or OFF.

Cool Down Time

Sets the period of cool down time.