Summary of Contents for National Instruments NI 9219E

  • Page 1 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
  • Page 2 OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9219E 4-Channel, 24-Bit, Universal Analog Input Module Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3 This document describes how to use the National Instruments 9219E and includes dimensions, terminal assignments, and specifications for the NI 9219E. Visit and enter ni.com/info rdsoftwareversion to determine which software you need for the modules you are using. For information about installing, configuring, and programming the system, refer to the system documentation.
  • Page 4 NI 9219E Dimensions The following figure shows the dimensions of the NI 9219E. 73.4 (2.89) 0.0 (0.00) Figure 1. NI 9219E Dimensions in Millimeters (Inches) © National Instruments Corp. NI 9219E Operating Instructions and Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 5 Connecting the NI 9219E The NI 9219E has four 6-terminal spring-terminal connectors that provide connections for four analog input channels. Ch 0 Ch 1 Ch 2 Ch 3 Figure 2. NI 9219E Channel and Terminal Assignments NI 9219E Operating Instructions and Specifications ni.com...
  • Page 6 Table 1. NI 9219E Signal Names Terminal Signal Name Signal Description TEDS Data T– TEDS COM EX+/HI Positive excitation or input signal Positive input signal EX–/LO Negative excitation or input signal Negative input signal Depending on the mode, terminals 3 and 5 are either the excitation signals or the input signals.
  • Page 7 Table 2. NI 9219E Terminal Assignments by Mode Terminal Mode – Voltage — — – Current — — – – 4-Wire Resistance – 2-Wire Resistance — — – Thermocouple — — – – 4-Wire RTD – – 3-Wire RTD —...
  • Page 8 Specifications section for more information about spring-terminal wiring. Refer to Figure 3 for an illustration of connecting wires to the NI 9219E. © National Instruments Corp. NI 9219E Operating Instructions and Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 9 Figure 3. Connecting Wires to the NI 9219E Spring-Terminal Connectors Connecting TEDS Channels The NI 9219E supports only Class II TEDS sensors. Connect the two TEDS lines to TEDS Data (T+) and TEDS COM (T–) and ensure that neither T+ nor T– is tied in common to any of the signal inputs (terminals 3 through 6) on the NI 9219E.
  • Page 10 Connecting Signal Sources to the NI 9219E You can connect ground-referenced or floating signal sources to the NI 9219E. If you make a floating connection between the signal source and the NI 9219E, make sure the voltages on the positive and negative connections are within the channel-to-earth working voltage range to ensure proper operation of the NI 9219E.
  • Page 11 Twisted-Pair Shielding Wiring Signal Source NI 9219E – Ground Reference Figure 4. Connecting a Grounded Signal Source to the NI 9219E Twisted-Pair Shielding Wiring Signal Source NI 9219E – Figure 5. Connecting a Floating Signal Source to the NI 9219E NI 9219E Operating Instructions and Specifications 10 ni.com...
  • Page 12 NI 9219E – TEDS Isolated Filter Figure 6. Input Circuitry for One Channel on the NI 9219E © National Instruments Corp. 11 NI 9219E Operating Instructions and Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 13 Voltage and Current Modes In Voltage mode, the ADC measures voltage across the HI and LO terminals. In Current mode, the NI 9219E computes current from the voltage that the ADC measures across an internal shunt resistor. – NI 9219E...
  • Page 14 4-Wire Resistance and 4-Wire RTD Modes In 4-Wire Resistance and 4-Wire RTD modes, the NI 9219E sources a current, which varies based on the resistance of the load, between the EX+ and EX– terminals. The NI 9219E computes measured resistance from the resulting voltage reading. Lead wire...
  • Page 15 This mode compensates for lead wire resistance in hardware if all the lead wires have the same resistance. The NI 9219E applies a gain of 2x to the voltage across the negative lead wire and the ADC uses this voltage as the negative reference to cancel the resistance error across the positive lead wire.
  • Page 16 In 2-Wire Resistance and Quarter-Bridge modes, the NI 9219E sources a current, which varies based on the resistance of the load, between the HI and LO terminals. The NI 9219E computes measured resistance from the resulting voltage reading. 2-Wire Resistance and Quarter-Bridge modes do not compensate for lead wire resistance.
  • Page 17 1 The dotted line represents the portion of the circuit that is connected only in Full-Bridge mode. Figure 11. Connections in Half-Bridge and Full-Bridge Modes NI 9219E Operating Instructions and Specifications 16 ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 18 Thermocouple Mode In Thermocouple mode, the NI 9219E uses the ±125 mV range of the ADC to return a voltage reading. Use shielded cables and twisted pair wiring and ground the shielded cables. Each channel has a built-in thermistor for cold-junction compensation (CJC) calculations.
  • Page 19 Refer to Figure 7 for an illustration of the connections. Open Contact Mode In Open Contact mode, the NI 9219E sources a current between the HI and LO terminals and determines if the two terminals are open or closed based on the measured current through the terminals.
  • Page 20: Excitation Protection

    NI 9219E Timing Options The NI 9219E supports four different timing options that are optimized for different types of applications by using different ADC conversion times. High Speed is optimized for high speed at the expense of noise rejection, Best 60 Hz Rejection is optimized...
  • Page 21: Sleep Mode

    Input Characteristics Number of channels......4 analog input channels ADC resolution......... 24 bits NI 9219E Operating Instructions and Specifications 20 ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 22 390 Ω, 150 Ω Quarter-Bridge Half-Bridge ±500 mV/V ±500 mV/V Full-Bridge ±62.5 mV/V, ±62.5 mV/V, ±7.8 mV/V ±7.8125 mV/V © National Instruments Corp. 21 NI 9219E Operating Instructions and Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 23 Overvoltage protection Terminals 1 and 2 ....... ±30 V Terminals 3 through 6, across any combination ....±60 V NI 9219E Operating Instructions and Specifications 22 ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 24 Resistance, 10 kΩ ±0.1, ±0.5 ±120, ±320 4-Wire and 2-Wire Resistance, 1 kΩ ±0.1, ±0.5 ±1200, ±3200 © National Instruments Corp. 23 NI 9219E Operating Instructions and Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 25 2-Wire Resistance mode accuracy depends on the lead wire resistance. This table assumes 0 Ω of lead wire resistance. Cold-junction compensation sensor accuracy ......... ±1°C typ NI 9219E Operating Instructions and Specifications 24 ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 26 Quarter-Bridge, 350 Ω ±15 ±120 Quarter-Bridge, 120 Ω ±15 ±240 ± Half-Bridge, 500 mV/V ±3 ±20 © National Instruments Corp. 25 NI 9219E Operating Instructions and Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 27 Voltage, ±4 V 10.8 Voltage, ±1 V Voltage/Thermocouple, ±125 mV 10.8 Current, ±25 mA 10.8 4-Wire and 2-Wire Resistance, 10 kΩ NI 9219E Operating Instructions and Specifications 26 ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 28 Input bias current ......<1 nA INL............ ±15 ppm = 60 Hz) ......>100 dB CMRR (f © National Instruments Corp. 27 NI 9219E Operating Instructions and Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 29 Excitation (V) Half-Bridge Full-Bridge Excitation level for Resistance, RTD, and Quarter-Bridge modes Load Resistance (Ω) Excitation (mV) 10 k 2200 NI 9219E Operating Instructions and Specifications 28 ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 30: Power Requirements

    Thermal dissipation (at 85 °C) Active mode ....... 625 mW max Sleep mode ......... 25 μW max © National Instruments Corp. 29 NI 9219E Operating Instructions and Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 31: Physical Characteristics

    Spring-terminal wiring...... 18 to 28 AWG copper conductor wire with 7 mm (0.28 in.) of insulation stripped from the end Weight..........60 g (2.1 oz) NI 9219E Operating Instructions and Specifications 30 ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 32 Measurement Category II, (Double insulation) Withstand........2,300 VAC, verified by a 5 s dielectric withstand test © National Instruments Corp. 31 NI 9219E Operating Instructions and Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 33 230 V for Europe. Do not connect to signals or use for Caution measurements within Measurement Categories III or IV. NI 9219E Operating Instructions and Specifications 32 ni.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 34: Online Product Certification

    Certification column. Environmental National Instruments C Series modules are intended for indoor use only but may be used outdoors if installed in a suitable enclosure. Refer to the manual for the chassis you are using for more information about meeting these specifications.
  • Page 35: Environmental Management

    Maximum altitude......2,000 m Pollution Degree ....... 2 Environmental Management National Instruments is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.
  • Page 36 China RoHS compliance, go to ni.com/ environment/rohs_china Calibration You can obtain the calibration certificate and information about calibration services for the NI 9219E at ni.com/calibration Calibration interval ......1 year © National Instruments Corp. 35 NI 9219E Operating Instructions and Specifications...
  • Page 37: Where To Go For Support

    Where to Go for Support The National Instruments Web site is your complete resource for technical support. At you have access to ni.com/support everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers.
  • Page 38 Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545 National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.
  • Page 39 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...