Pairing controls
LED indicator 1
Button 1 2
Button 2 3
Activating button 4
Press the Code button until the
LED 1 shines continuously.
Within 10 seconds, press button
1 or 2 of the remote control, or
the activating button of the wall
control.
Press the same button again.
LED 1 will fl ash and turn off .
Repeat steps 1. to 3. to code
up to a maximum of 10 remote
controls.

Safety reversal system test

With the door fully open, place
a board with a thickness of 5 cm
centered in the way of the door.
Press remote control push but-
ton. When closing, the door
MUST reverse when making
contact with the board.
Otherwise do not use the
garage door opener any more;
instead seek professional assis-
tance for repair.
212
|
ENGLISH
3
Remote control
2
1.
1.
2.
3.
WARNING
Without a properly installed safety reversal system, persons (particu-
larly small children) could be seriously injured or even killed by a clos-
ing garage door. Incorrect adjustment of garage door travel limits will
interfere with the proper operation of the safety reversal system.
The safety reversal system MUST be tested at least once every
month.
The safety reversal system must be tested after any adjustments
made.
1.
2.
1.
Wall control
1
3
2.
< 10 sec.
2.
4
< 10 sec.

Advertisement