VENTO V50-1 / V50-1 S / V50-1 Pro / V50-1 S Pro www.blaubergventilatoren.de CONTENTS Introduction General Safety rules Transportation and storage rules Manufacturer's warranty Design and operating logic Modifications and options Delivery set Technical data Mounting Connection and control Maintenance Troubleshooting Acceptance certificate Connection certificate...
VENTO V50-1 / V50-1 S / V50-1 Pro / V50-1 S Pro www.blaubergventilatoren.de BLAUBERG Ventilatoren GmbH is happy to offer your attention the new equipment to prevent back drafting. The maximum permitted pressure reversible ventilation heat recovery single-room unit VENTO V50-1.
VENTO V50-1 / V50-1 S / V50-1 Pro / V50-1 S Pro www.blaubergventilatoren.de DESIGN AND OPERATING LOGIC The unit consists of a telescopic duct with adjustable length, a ventilation The built-in filter with filter class G3 are used for supply and extract air unit and an outer ventilation hood.
VENTO V50-1 / V50-1 S / V50-1 Pro / V50-1 S Pro www.blaubergventilatoren.de Phase 1 (70 seconds) Phase 2 (70 seconds) Air supply to the room Air extraction from the premise +20 °С +17 °С OUTSIDE INSIDE OUTSIDE +17 °С +20 °С...
VENTO V50-1 / V50-1 S / V50-1 Pro / V50-1 S Pro www.blaubergventilatoren.de TECHNICAL DATA Table 1. Technical data of the unit Parameters Vento V50-1 / VENTO V50-1 Pro / VENTO V50-1 S / VENTO V50-1 S Pro Supply Voltage / 50 Hz [V] 220-240 Speed Total unit power [W]...
VENTO V50-1 / V50-1 S / V50-1 Pro / V50-1 S Pro www.blaubergventilatoren.de MOUNTING WARNING The air duct of the ventilation unit must not be closed with curtains, drapes and other clothes to avoid dust accumulation on the materials. The curtains may impair air circulation in the room and efficiency of the ventilation unit. The unit is designed for external through-the-wall installation inside a In case of brand new construction the units are mounted in two stages: •...
Page 8
VENTO V50-1 / V50-1 S / V50-1 Pro / V50-1 S Pro www.blaubergventilatoren.de 3. Fix the inner part of the telescopic air duct on inner wall side using the 4. Fill the gaps between the wall and the telescopic air duct with a mounting screws 3x25 from the delivery set, Fig.
Page 9
VENTO V50-1 / V50-1 S / V50-1 Pro / V50-1 S Pro www.blaubergventilatoren.de • 11. Disassemble the outer ventilation hood to enable access to the fastening Fig. 16b - for VENTO V50-1 S. Loosen these 5 screws and take off the front holes: part of the outer ventilation hood.
VENTO V50-1 / V50-1 S / V50-1 Pro / V50-1 S Pro www.blaubergventilatoren.de 17. Install the power and control unit in the wall recess, Fig. 20. 18. Install the frame, the buttons and the plug in the reverse order, Fig. 21. Fig.
Page 11
VENTO V50-1 / V50-1 S / V50-1 Pro / V50-1 S Pro www.blaubergventilatoren.de All electric connection to the control unit and the ventilator are performed with the socket connectors (detachable terminal blocks) for mounting and Extract/supply mode* Second speed mode Unit on servicing facilitation.
Page 12
VENTO V50-1 / V50-1 S / V50-1 Pro / V50-1 S Pro www.blaubergventilatoren.de Connection of the unit in compliance with the wiring diagram in Fig. 25 The inputs on the controller socket connectors are marked 21 to 25. The enables synchronous connection of 2 up to 4 units. In this very case the 12W outputs on the controller socket connectors are marked 11 to 15.
Page 13
VENTO V50-1 / V50-1 S / V50-1 Pro / V50-1 S Pro www.blaubergventilatoren.de Up to 12 VENTO V50-1 units may be connected to a single SEA control panel Connect all the other units, up to 12 items, in the same way. powered by the 40W power transformer AT-40, Fig.
Page 14
VENTO V50-1 / V50-1 S / V50-1 Pro / V50-1 S Pro www.blaubergventilatoren.de The control panel SEA is capable of controlling many connected units. Connection example with several transformers is shown in Fig. 27. In this case a required number of the transformers AT-12 or AT-40 must be used for power supply.
VENTO V50-1 / V50-1 S / V50-1 Pro / V50-1 S Pro www.blaubergventilatoren.de MAINTENANCE WARNING! Disconnect the unit from power mains prior to maintenance operations! The unit technical maintenance consists in the periodic cleaning of the vacuum cleaner. Let the filter dry and install the dry filter inside the unit surfaces and cleaning or replacement of the filters.
Company: Name: Date Signature WARRANTY CARD VENTO V50-1 Pro VENTO V50-1 VENTO V50 -1 S Pro VENTO V50 -1 S SELLER SALES DATE REPRESENTATIVE IN EU BLAUBERG Ventilatoren GmbH Aidenbachstr. 52a, D-81379 Munich, Germany...