Nuvo-6108GC/ Nuvo-6108GC-IGN
[BIOS POST Check]
This option secures a boot-to-OS operation. If the system is
failed to boot to OS (e.g. disk failure or no bootable device)
Enabled
within 60 seconds, ignition control module will cut off system
power and retry another power on cycle.
Disabled
BIOS POST check is skipped.
[Power On Delay]
Specifies the power-on delay duration. Once IGN signal goes active and
sustains for the duration of power-on delay, ignition control module turns on
system power and boot up the system.
[Power Off Delay]
Specifies the power-off delay duration. Once IGN signal goes inactive and
sustains for the duration of power-off delay, ignition control module performs
system shutdown (soft-off) and then cut off system power.
[Hard-off Timeout]
Specifies system hard-off timeout. Once system failed to normally shutdown via
a soft-off operation due to system/application halts (e.g. Windows BSOD),
ignition control module can compulsively cut off system power after the given
hard-off timeout.
[Battery Voltage]
Specifies the battery voltage of the vehicle where System VTC is deployed.
Typically it's 12 VDC for sedan and 24 VDC for bus/truck.
[Low Battery Threshold]
When system is running, ignition control module continuously monitors the
battery voltage. Once the battery voltage is lower than the specified threshold, it
performs system shutdown (soft-off) and cut off system power to prevent battery
drain-out. You should specify the low battery threshold according to the given
battery voltage.
Press F10 to "Save Changes and Exit". The ignition control module will be reset
and operate according to parameters configured in BIOS setup menu.