3. How to Read the LCD Display (continued from previous page)
RTR-505-P (Pulse)
There are two display methods for the pulse measurement. By using the
software included with the Base Unit, you can change the display method.
Pulse Rate (Max: 61439)
The most recent pulse count (Unit: P) for the record-
ing interval period will be displayed. The display
will be refreshed every one-sixtieth of the recording
interval (at minimum of every one second). 10,000
pulse count will be displayed as "10.00KP", in units
of 10 pulse for display.
Total Pulse Count
The cumulative number of pulses (Unit: P) will be
displayed from 0 to 9999. The displayed count will
be refreshed every one second, and upon exceed-
ing 9999, the count will start over again from 0.
Other Marks or Messages on Display
Logging Capacity FULL
When Recording Mode has been set to "One Time" and
the Unit reaches its logging capacity of 16,000 readings,
recording will automatically stop and in the LCD the mea-
surement and the word "FULL" will alternately appear.
Estimation of time until "FULL" is displayed
Recording
1 second
30 seconds
1 minutes
10 minutes
60 minutes
Interval
About 1 year and
Period
About 4 hours About 5 days About 11 days About 111 days
10 months
Data Transmission via Wireless Communication
The measurement and the word "SEnd" will alternately
appear when data is being sent via wireless communi-
cation to the Base Unit. Recording will continue during
wireless transmission.
Check
If this appears, all data that was stored in the Unit will
have been erased.
This message will appear under the following conditions:
- The first time a battery was inserted after purchase
- When the battery is replaced after having been taken out for a long period
- When the battery is replaced after the battery power has been lost
4. Registering as a Remote Unit (Communication with a PC)
In order to download data from the Unit via wireless communication or change recording settings in the Unit, it is necessary to
register a RTR-505 Unit as a Remote Unit to a Base Unit (sold separately). Remote Unit registration can be carried out by
connecting the Base Unit to a PC via USB cable and using the software included with the Base Unit to carry out optical
communication with the Remote Unit.
For details about available operations via wireless communication or how to make recording settings, see the Introductory
Guide included with the Base Unit or see the application's Help.
Communicating with the Computer
1.
Follow directions as issued in the software to connect
the Base Unit to your PC.
Communication Cable
2.
Place the Data Logger on the Base Unit to align the
optical communication areas and slitted areas.
RTR-505
Ex: RTR-500
Optical
Communi-
cation Area
Slitted Area
Input Module Unrecognized (factory default)
This will appear if, after purchasing, the Input Module
has never been connected to the Unit. (No unit for
display)
Note that a RTR-505-P has been set to measure Pulse by
default, therefore the unit "P" will be displayed.
Input Module Unconnected or Damaged
This will appear if the Unit cannot confirm a connec-
tion with the Input Module after having recognized it.
(with unit of display)
If nothing is displayed after reconnecting the sensor to the
Unit, there is a possibility that the sensor or the Unit has been
damaged.
Sensor Unconnected or Damaged
This will be displayed when a sensor has not been
connected to the module or the wire has been broken.
Recording is in progress and so is battery consump-
tion.
If nothing appears on display after reconnecting the sensor to
the Unit, there is a possibility that the sensor or the Unit has
been damaged.
Measurement Range Exceeded
The message "OL" will appear if a measurement ex-
ceeds the measurement range.
Display Range Exceeded
When measuring voltage, the measurement in the
LCD display will blink if a measurement exceeds a set
display range. (Only when the Unit has been set to a
"fixed decimal point" for display)
Communication with a PC enables the following:
By using a software included with the Base Unit, it is possi-
ble to carry out Remote Unit registration, change recording
settings in the Unit, download recorded data to a PC, and
view downloaded data.
The factory default settings are as follows: Recording Interval: 10 minutes, Recording
Start: Immediate Start, and Recording Mode: Endless.
Notices about Optical Communication with a Base Unit
- Proper communication may not be possible in the following situations: where tem-
peratures are very high or very low, in an environment with intense brightness (higher
than 5,000lx), or when the remaining battery life for the Data Logger is very low.
- The time necessary to download one RTR-505 Unit at full logging capacity varies
depending upon the Base Unit being used.
Distributed by MicroDAQ.com, Ltd.
www.MicroDAQ.com
(603) 746-5524
Important Notices and Disclaimers
In order to properly use this product, please carefully read this manual before using.
T&D Corporation accepts no responsibility for any malfunction of and/or trouble with this product or with your computer that is caused by the improper handling of this product
and will deem such trouble or malfunction as falling outside the conditions for free repair outlined in the attached warranty.
- All rights of this manual belong to T&D Corporation. It is prohibited to use, duplicate and/or arrange a part or whole of this Manual without the permission of T&D Corporation.
- All registered trademarks, company names, product names and logos mentioned herein are the property of T&D Corporation or of their respective owners.
- Specifications, design and other contents outlined in this manual are subject to change without notice.
- Please follow the safety precautions outlined in this manual carefully. We cannot guarantee nor are we responsible for safety if this product is used in any manner other than was intended.
- On-screen messages in this manual may vary slightly from the actual messages.
- Please notify the shop where you purchased this product or T&D Corporation of any mistakes, errors or unclear explanations in this manual.
- T&D Corporation accepts no responsibility for any damage or loss of income caused by the use of our product.
- This product has been designed for private or industrial use only. It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment, whether directly or indirectly.
- We are not responsible for any malfunction or trouble caused by the use of our product or by any problem caused by the use of measurement results of our unit. Please be fully aware of this before using our product.
- This manual cannot be reissued, so please keep it in a safe place.
- Please read the warranty and provisions for free repair carefully.
Safety Precautions and Instructions
* Please carefully observe the following safety measures when using our product.
To prevent any loss or damage to our customers, other people and/or property, and to ensure the proper use of our products we ask that before using our product you carefully
read, understand and follow the safety rules and precautions for our products as outlined below.
DANGER
Do not take apart, repair or modify the Unit.
It may result in malfunction or unexpected accidents.
Do not use any other batteries than those that are specified in this manual.
It may cause fire or malfunction.
If water or a foreign object enters the case, immediately remove the battery
and cease using it.
It may result in malfunction or unexpected accidents.
Store the Unit and accessories out of the reach of children.
Not doing so may cause an unexpected accident.
If any smoke or strange smells are emitted from the Unit, immediately remove
the battery and stop using.
Continued use may cause fire or electrocution.
Please be careful not to touch the Unit during or after use in overly hot or cold
environments; it may cause burns or frostbite.
CAUTION
This Unit has been designed for private and/or industrial use only. It is not for
use in situations where strict precautions are necessary such as in connection
with medical equipment, where directly or indirectly.
Harmful gases or chemicals may cause corrosion and/or other danger to the
Unit. Also, by coming in contact with hazardous substances, harm may occur
to the people handling the Unit. Therefore, do not use or store the Unit in any
environment that is exposed to chemicals and harmful gases.
Battery life varies depending upon measuring environment, frequency of
communication, Unit settings, and battery performance.
When using the Unit in a low-temperature environment (below -20°C), the
battery power will be depleted more quickly than when using under normal
temperature conditions.
Battery terminals may provide insufficient contact due to age or vibration.
This may lead to data loss.
The Unit becomes splash proof (rated for use in daily life) only after the Input
Module has been connected.
Without the module connected, neither the module jack nor the connector part of the temperature
sensor on the Unit is water resistant; make sure not to get wet.
If the Unit is not to be used for a long period of time, store it in a place where it
is not exposed to high temperature and high humidity.
If the Unit has condensation on the inside, it may cause malfunction and damage.
Do not remove or reinsert the battery once it has been set; continue using until
battery power is depleted. Always use a new battery for replacement.
Not doing so may result in improper operation.
To maintain waterproof capacity, we suggest periodically changing the parts
inside the case.
If the rubber packing should be damaged or deteriorated, please replace it along with the drying
agent.
If the Unit is subjected to significant temperature change while wet, it may
cause condensation inside the case.
Especially be careful with temperature changes from high to low; if the Unit has condensation on
the inside, it may cause malfunction, damage, and/or unexpected accidents.
Do not drop or expose the Unit to a strong impact.
It may cause damage or malfunction.
Do not put fingers or foreign objects into the modular jack.
Do not use or store the Unit in places such as listed below. It may result in
malfunction or unexpected accidents.
- Areas exposed to direct sunlight
- Areas exposed in water or high-pressure water flow
- Areas exposed to organic solvents and corrosive gas
- Areas exposed to strong magnetic fields
- Areas exposed to static electricity
- Areas near fire or exposed to excessive heat
- Areas exposed to excessive dust, dirt and smoke
Contact with oil may cause cracks to appear in the casing of the Unit.
When using this Unit in environments where such oils are present, please
insure that it is protected from contact through use of a polyethylene bag
or other means.
Notices about using the Input Modules
When making "Adjustment Settings" in the Adjustment Tools application, the
adjustment values will be saved to the Input Module. Therefore, when an Input
Module is replaced, it is necessary to re-make any desired adjustment settings to be
written into the newly connected module.
Compliance Information
FCC Statement
This device complies with Part 15 of the Federal Communications Commission
(FCC) rules. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired operation.
Caution: Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
Note about Antenna Usage: This device has been designed to operate with the supplied antenna only.
Use of any other antenna is strictly prohibited.
IC Statement
This device complies with RSS-210 of the Industry Canada (IC). Operation is
subject to the following two conditions: (1) This device may not cause harmful
interference; and (2) This device must accept any interference received, including
interference that may cause undesired operation.
Ce dispositif est conforme à la norme RSS 210 d'Industrie Canada.
L'utilisation de ce dispositif est autorisée seulement aux conditions suivantes : (1)
il ne doit pas produire de brouillage et (2) l'utilisateur du dispositif doit être prêt à
accepter tout brouillage radioélectrique reçu, même si ce brouillage est
susceptible de compromettre le fonctionnement du dispositif.
Important Notice
Wireless products cannot be used in countries other than where those products have
been approved for use, according to that country's wireless regulations.
T&D Corporation shall in no manner whatsoever take responsibility for the usage of
these products, nor be liable in any manner for legal consequences stemming from
the usage of these wireless products in unapproved areas.
Wireless Data Recorder RTR-505 Warranty
1 year from date of purchase
Guarantee Period
Date of Purchase
Customer's name
Address
Phone No.
Distributor's name
Address
Phone No.
Main Unit (excluding sensors and any other options.)
Object of Repair
Method of Repair
Send in for Repair
Provisions for Free Repair
1. If the Unit does not work properly despite the fact that the customer used it properly and in line with
the manual, the Unit shall be repaired free of charge through the distributor which sold the Unit.
2. If the customer requests free repair because of trouble within the warranty period, bring or send the
Unit along with the warranty to the distributor.
3. If you have moved after purchasing, or there are difficulties contacting the distributor from which you
purchased the Unit, please contact T&D directly for service.
4. Free repair is not available in the following cases even though it is within the warranty period:
1. Trouble or damage was caused by careless operation, natural disaster, fire, public pollution, or use
of a power source other than specified.
2. If repair, adjustment, disassembly or modification of the Unit has been carried out by a person other
than a T&D authorized engineer.
3. Trouble or damage was caused by transportation, movement or dropping of the Unit after pur-
chase.
4. Failure to submit the Warranty or failure to fill in all items required in the Warranty.
5. The Warranty cannot be reissued.
This Warranty only promises customers free repair within the period and conditions clarified in this
Warranty. Therefore, the customer's legal rights will not be limited by this Warranty. For further infor-
mation on repair and other service questions after the termination of the warranty period, contact your
distributor.

Advertisement

loading

This manual is also suitable for:

Rtr-505vRtr-505pt