Digital timer

Advertisement

GEMO
Mode : 0;
ON Delay
Out becomes ON "t.SEt" after START
Start
input is ON. Out is OFF when START
input is OFF. Out is OFF when RESET
t.SEt
Out
input is ON .
Mode : 1;
Pulsed Delay, OFF with RESET
Out becomes ON "t.SEt" after START
Start
input is triggered (OFF > ON). START
input can not re-trigger timer until it is
Reset
reset with RESET input. Out is OFF
t.SEt
when RESET input is ON .
Out
Mode : 2;
Retriggerable One Shot
Out becomes ON when START input
Start
is triggered (OFF > ON) and becomes
OFF after "t.SEt". START input can
t.SEt
re-trigger when Out is ON. Out is OFF
Out
when RESET input is ON .
Mode : 3;
Non-retriggerable One Shot
Out becomes ON when START input is
Start
triggered (OFF > ON) and becomes OFF
after "t.SEt". START input can not
t.SEt
re-trigger when Out is ON. Out is OFF
Out
when RESET input is ON .
Mode : 4;
Delay after Power ON
Out becomes ON "t.SEt" after Power ON.
Enerji
START input does not trigger timer.
t.SEt
Out is OFF when RESET input is ON .
Out
Mod : ;
e 5
OFF Delay
Out becomes ON when START input is
Start
ON. Out becomes OFF "t.SEt" after START
t.SEt
input is triggered (ON > OFF). Out is OFF
Out
when RESET input is ON .
Mode : 6;
One Shot after OFF
Out becomes ON when START input is
Start
triggered (ON > OFF) and becomes OFF
t.SEt
after "t.SEt". Out is OFF when START
Out
is ON. Tx is OFF when RESET input is O .
Notes:
1. For Modes 8 & 9; t.On and t.OFF are accepted as min. 000.1 sec, 00.01 min. and 00.01 hr. .
2. Timer counts up for Mode 11 & 12, and down for other modes.
3. For all modes; counting is inhibited (or freeze) when GATE is ON.
Do not use any solvents (alcohol, thinners, benzine, acid, etc.) or corrosive substances to clean the device.
Use only a dry and clean non-abrasive cloth. Before cleaning, disconnect the power supply and mains
connections.
Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti.
Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye
Tel: +90-312-3503900, Fax: +90-312-3511117
MODES OF OPERATION
Mode : ; 7
Start
t.SEt
Out
Mode : ; 8
Start
t.On
Out
Mode : 9;
Start
Reset
t.On
Out
Mode : 10;
Start
Out
Mode :
11 Chronometer
Start
t.SEt
Gösterge
Out
Mode : 2;
1 Chronometer
Start
t.SEt
Gösterge
Out
Reset
CLAEANING
4
One Shot after ON and OFF
Out becomes ON when START input is
triggered (OFF > ON) or (ON > OFF) and
t.SEt
t.SEt t.SEt
becomes OFF after "t.SEt". START input
can re-trigger when Out is ON. Out is OFF
when RESET input is ON.
Flashing with START
Out is periodically first ON for "t.On" and then
OFF for "t.OFF" when START input is ON. Out
t.OFF
t.On
t.OFF
is OFF when START input is OFF. Tx is OFF
when RESET input is ON
Flashing with START/RESET
Out is periodically first ON for "t.On" and then
OFF for "t.OFF" after START input is triggered
(OFF > ON). Out is OFF when RESET input
t.OFF
t.On
t.OFF
is ON.
Delayed One Shot after OFF
Out is first ON after "tA" and then OFF after
"tB" when START is triggered (ON > OFF).
tA
tB
START input does not re-trigger before "tB"
elapses. Out is OFF when RESET input is ON.
;
- Count with START
Out is ON and timer counts up when START
is ON. Timer freezes when START is OFF.
Timer resets when START is OFF if Timer
has elapsed `T.SEt` time. Out is OFF when
RESET input is ON.
- Count with START, Reset with RESET
Timer counts up when START is ON. Timer
freezes when START is OFF. Out is ON if Timer
has elapsed `T.SEt` time. Timer resets and Out
is OFF when RESET input is ON.