THE ILP is sparking, but not at the nozzle:
This is possibly an ignition rod failure. Replace the rod by unscrewing the rod from the base of the ILP and
replacing it with a new rod.
It has been determined that the ILP nozzle and/or the ignition rod need to be replaced:
Unscrew the nozzle or ignition rod and re-insert replacement components.
Use a high temperature anti-seize compound sparingly on the threads. Approved anti-seize compounds
include silver and copper-based products rated at 1600°F (871°C) or above. Avoid over application of
anti-seize product.
Previous process pilot required a higher psi to keep the supply line from freezing:
It is not necessary to operate at pressures above 6 psi with this pilot as it will still function below the normal
operating range, even in adverse conditions.