Gas Test
1. Connect the ILP to the gas line.
2. Press the Ignite button to initiate sparking.
3. The ILP will spark and ignite the gas flowing up to the nozzle.
4. As soon as there is flame, the sparking will stop and the BMS will switch to flame detection.
Please note: The flame is very efficient and may be difficult to see in daylight or direct light. Check that the
Flame LED on the BMS is on.
Once you have successfully completed the system tests, turn off the flame and proceed with installing the
system in your application.
Please note: Testing with a gas other than the process fuel may have different results.

3. Install the System

Secure the ILP to the burner using clamps that fit your specific installation and the provided struts. Assemble the
hardware as shown in the following diagram: