Open the door (follow the instructions on how to clean
the glass). Place the Thermotte as show in the
illustrations.
Powerstone is an accessory. For assebling see a
separate instruction.
Flue collar and connection
turned around FIG 4B.
National requirements. For the connection to the
chimney, follow the recommendations from the chimney
manufacturer
It is recommended to use the insert a few times in order
to let the varnish harden before any eventual masking
and painting. Only use water based breathing paint and
a designated masking tape. Carefully remove the tape
in order not to damage the varnish.
When the insert is installed and all instructions have
Take care when inserting logs into the burn chamber,
in order not to damage the Thermotte plates. Please
note that there might be some humidity in the insulation
few times the insert is used. This will be resolved once
the humidity has evaporated. If needed leave the door
release some smoke or smell. Both the smoke and
smell will disappear and are not hazardous.
In order to avoid injuries, please be aware that the
surfaface may become hot during operation and that
extra care need to be taken to avoid skin burn.
Kindling wood
Finely chopped (diameter of 3-5cm)
Length: 25-30cm
Ca. amount pr lighting : 2 kg
Place the air vent control in ignition mode (B). Insert
are stable and the chimney is warm, pull the air control
20
When there is a glowing layer of ash, new wood logs
can be inserted. Pull the hot ember to the front of the
combustion chamber when inserting new logs so that
Reload size
Chopped wood (diametre of 6-9cm)
Length: 25-50cm
Normal load size. 1,86 kg /h
around the clock increase pollution as well as the risk
should this happen. Regulation of the air vent control
takes some experience, but after a little while a natural

6. Maintenance

The insert should be inspected thoroughly and cleaned
at least once per season (possibly in combination
with the sweeping of the chimney and chimney pipes).
Ensure that all joints are tight and that the gaskets are
rightly positioned. Exchange any gaskets that are worn
or deformed.
Remember that the insert must always be cold when
inspected.
Ashes
The ashes should be removed at regular intervals.
Be aware that the ashes can contain hot ember even
of non-combustible material to remove the ashes. It is
recommended to leave a layer of ashes in the bottom
as this further insulates the burn chamber. Take care
with the Thermotte plates when the ashes are removed,
particularly when using an ash shovel, so as not to
damage them.