Sensor type
·
Sensor lifespan
·
Sensor range
·
Detection range
·
Power consumption
·
Operating temperature
·
Humidity
·
Sound pressure
·
Alarm muting
·
Installation location

Functional principle and features

·
·
Functional principle and features
Electrochemical
7 years
0 to 1,000 ppm
max. 60 m²
< 80 µA (Ø standby) || < 25 mA (Ø alarm)
0° to 40° C
30% to 95% (non-condensing)
> 85 dB (A)@1 m (3.5 +/- 0.5 kHz pulsing)
5 minutes
Wall
According to EN 50291, the COWM300 ABUS CO alarm is
designed and approved exclusively for detecting CO (carbon
monoxide) in private homes.
Application in industrial facilities, offices, boats, caravans or
mobile homes is therefore not permitted.