FAQ - English
Fault
If the burner will
not light in spite
of the gas shutoff
valve being open
and no gas is
heard escaping.
If the burner will
not light even
though there is
a loud noise of
escaping gas.
If there is a smell
of gas when the
burner is alight.
Cause
• Central gas supply has
not been turned on /
gas bottle is empty.
• Jets are blocked or
dirty.
• Strong draught in the
area of the burner.
• Incorrect type of gas or
supply pressure.
• Connections are leak-
ing.
• Burner is leaking.
- 1 -
Remedy
• Operational error.
• Screw off burner tubes
and carefully clean the
jets with a soft cloth.
Do not screw out the
jets!
• Eliminate the draught,
reposition the burner.
• Check supply pressure
and type of gas.
• Check the connections.
• If the burner leaks do
not carry out repairs
yourself, send burner
for inspection.