Bogen MT60 Manual
Bogen MT60 Manual

Bogen MT60 Manual

60-watt and 125-watt booster amplifiers

Advertisement

Quick Links

Solid-State PA Components
I N S T A L L A T I O N
UNPACKING
The amplifier was thoroughly checked before leaving the
factory. Inspect the amplifier and shipping container
carefully for evidence of improper handling during ship-
ment. In case of damage, make an immediate claim to the
dealer or distributor from whom the unit was purchased. If
the amplifier was shipped to you, notify the carrier without
delay and file a claim.

INPUT CONNECTIONS

Keep the input lead away from the output lead and ac
power cables. Unless the driving source provides a
low-impedance output, keep the input lead under ten feet
POWER OUTPUT:
PEAK OUTPUT:
E:
PUT SENSITIVITY (FOR
RATED OUTPUT): '
INPUT IMPEDANCE:
OUTPUT IMPEDANCE
(BALANCED OR UNBALANCED):
CONTROLS AND INDICATORS:
SEMICONDUCTORS:
POWER CONSUMPTION:
AUXPOWERRECEPTACLE:
OVERLOAD PROTECTION:
DIMENSIONS:
WEIGHT:
*Variations i n performance characteristics normally will not exceed I dB.
PRINTED IN U.S.A.
3-75
PMP #1390
MT60
60 watts
120 watts
±2 dB, 30 Hz to 20k Hz
Less than 2% at rated output
-80 dB below rated output
Less than 2 dB variation from no load to full load.
Hi Z 0.2V; Lo Z balanced with TL600 xfmr, .045V; Hi Z with TL 10k xfmr, 0.lV.
Hi Z 5 0 k ; Lo Z 500/60052 with TL600 xfmr; Bridging l O k with TL 10k xfmr.
25VCT; 10.4s2 (25V); 8R; 16R;
A
power switch, ac power indicator lamp, volume control, music-speech selector
C
s w i t c h .
6 silicon transistors; 7 diodes
120VAC 60HZ. 168 watts @Rated
output
120VAC 60HZ, 22 watts
(No Output)
48-56 VDC, 1 Amp @ 30 watts
output
48-56 VDC, 15 mA @ Quiescent (No
Output)
550
watts
Ac Circuit Breaker. 1 .65A Hold: DC
circuit breaker. I .65A Hold; Thermal
breaker, 95° C. with recovery in
approximately 2 minutes.
8" W. x 13" D. x 6¼" H.
18½ Ibs.
LEAR SIEGLER, INC.
TABLE I. COMPANION UNITS AND ACCESSORIES
Model
Five input solid-state preamplifier mixer.
CAM
CM
Five input solid-state preamplifier mixer.
CHS-M
Seven input solid-state preamplifier mixer.
CTM
Seven input solid-state preamplifier mixer.
MX6A-5
Six input solid-state preamplifier mixer.
RPK-I 8
Rack mounting kit 19" x 7" (mounts 2
units).
TL600
Low-impedance (500/6OOs1) plug-in
transformer.
TL10K
Bridging (1 Oka) plug-in transformer.
125 watts
250 watts
±2 dB, 40 Hz to 20k Hz
Less than 2% at rated output
-80 dB below rated output
25VCT; 5s2 (25V); 8R, 16R; 40R
(7OV)
8 silicon transistors; 7 diodes
120VAC 60HZ, 300 watts @ Rated
output
@ Quiescent
120VAC 60HZ, 30 watts @ Quiescent
(No Output)
48-56 VDC, 2.25 Amps @ 62.5 watts
48-56 VDC, 15 mA @ Quiescent (No
Output)
390 watts
AC circuit breaker. 2.5A Hold; DC
circuit breaker, 2.5A Hold; Thermal
breaker, 104" C. with recovery in
approximately 2 minutes.
8" W. x 13" D. x 6¼" H.
25 Ibs.
MODELS MT60
& MT125A
60-Watt and 125-Watt
Booster Amplifiers
Description
MT125A
54-5521-01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MT60 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bogen MT60

  • Page 1 MODELS MT60 & MT125A Solid-State PA Components 60-Watt and 125-Watt Booster Amplifiers I N S T A L L A T I O N TABLE I. COMPANION UNITS AND ACCESSORIES UNPACKING Description Model The amplifier was thoroughly checked before leaving the Five input solid-state preamplifier mixer.
  • Page 2 Refer to Table I for Bogen preamplifiers suitable OUTPUT CONNECTIONS for use with the amplifier. Speakers may be connected with standard flexible line cord (zip-cord) and up to 100 feet of cable may be used without appreciable loss. Class II wiring is acceptable unless HIGH IMPEDANCE INPUT: The amplifier can be driven to prohibited by local codes.
  • Page 3 BOGEN SERVICE We are interested in your Bogen equipment for as long as you have it. If trouble ever develops, do not hesitate to ask our advice or assistance. Information can be obtained by writing to Service Department, Bogen Division, P.O.
  • Page 4 Bogen, provided the equipment delivered or shipped prepaid and insured to our authorized service station or to the Bogen Factory Service Department, Route 4 and Forest Avenue, Paramus, New Jersey 07652. The equipment may be picked up by you personally or will be returned to you freight prepaid.

This manual is also suitable for:

Mt125a