GEWAS 191 and GEWAS 191A
Scope of supply:
1 x control device GEWAS 191 or GEWAS 191A
1 x water sensor GWF-1S
1 x solenoid GMV 191 12VDC
1 x bushing
1 x sieve insert
Specification:
Voltage supply :
Power rating:
max. switching current:
Solenoid:
Dimensions:
EMC:
Installation and commissioning:
1. Installation of solenoid
- Lock water feed lines.
- Insert sieve insert.
- Connect solenoid with wingnut to the water feed by means of a right-hand turn.
- Check for leakage by opening the water feed.
- Screw water connection tube to the outlet side of the solenoid (use existing sealing ring
or make sure that tube itself is properly sealed! ).
If the installation has been carried out correcly the wingnut can be tightend by hand.
In case of leakage check if sealing has been inserted and if all sealing surfaces are clean;
also check if the installation has been carried out correctly. If necessary repeat installation
process.
Advice for commissioning:
The solenoid will not be opened unless it has been connected to the activated control
device.
2. Installation of control device and water sensor
- Make it a rule to read the operating and maintenance advises before starting-up the
device.
- Place water sensor at desired position and fix it, if necessary.
- Connect water sensor and solenoid to the control device.
- Open water feed line unless you have already done so.
- Plug in control device into a socket outlet with earthing contact.
=> Device is now active, the solenoid is open.
- Check water connection for leakage.
- Connect device which is to be switched off in case of alarm to the socket outlet with earthing contact of the control device.
GREISINGER
D - 93128 Regenstauf • Hans-Sachs-Straße 26
Fon: 0049 9402 9383-0 • Fax: 0049 9402 9383-33 • Internet: www.greisinger.de
Operating Manual For
220/240V 50/60Hz (control device)
approx. 3 Watt
16A ohmic load (for GEWAS 191A only)
max. working pressure: 6bar servo controlled (pressure difference infeed/outfeed >0,5 bar)
control device:
126 x 79 x 54 mm (L x W x H)
solenoid:
82 x 52 x 41 mm
The GEWAS 191 and GEWAS 191A correspond to the essential protection ratings established in the
Regulations of the Council for the Approximation of Legislation for the member countries regarding
electromagnetic compatibility (2004/108/EG)
! Well done, your GEWAS device is now ready for use !
S01.0.0X.6C-10
electronic GmbH
page 1 of 2
water feed
(tap)
sieve insert
wingnut
water flow direction
solenoid
sealing ring
water feed tube