E44.X.00.6C-03 Connection and operating manual GIR 300 page 2 of 28 Index GENERAL NOTE ..............................3 INTENDED USE ................................ 3 SAFETY ..................................4 ..........................4 AFETY SIGNS AND SYMBOLS .............................. 4 AFETY GUIDELINES ............................. 4 KILLED PERSONNEL ELECTRIC CONNECTION ............................5 ............................
EASYBus-module. When leaving our factory the GIR 300 has been subjected to various inspection tests and is completely calibrated. Before the GIR 300 can be used, it has to be configured for the customer’s application.
E44.X.00.6C-03 Connection and operating manual GIR 300 page 4 of 28 Safety 3.1 Safety signs and symbols Warnings are labeled in this document with the followings signs: Caution! This symbol warns of imminent danger, death, serious injuries and significant damage to property at non-observance.
E44.X.00.6C-03 Connection and operating manual GIR 300 page 5 of 28 Electric connection Wiring and commissioning of the device must be carried out by trained and skilled personnel only. Wrong connection may lead to the destruction of the display device, in which case we cannot assume any...
E44.X.00.6C-03 Connection and operating manual GIR 300 page 6 of 28 4.3 Connection an input signal Please take care not to exceed the limitations of the inputs when connecting the device as this may lead to destruction of the device.
E44.X.00.6C-03 Connection and operating manual GIR 300 page 7 of 28 4.3.4 Connecting a 0-1V, 0-2V or 0-10V transmitter in 3-wire-technology Supply: for transmitter 0-1(10)V Sig. Transmitter 1V / 2V 1V / 2V 0-1(10)V Sig. Transmitter Supply: 9-28 VDC Supply:...
Page 8
E44.X.00.6C-03 Connection and operating manual GIR 300 page 8 of 28 Supply: for transducer Sig. Transducer Sig. Transducer Supply: 9-28 VDC Supply: 9-28 VDC Connection of a transducer (with separate power Connection of a transducer (without separate power supply) with TTL or PNP output...
E44.X.00.6C-03 Connection and operating manual GIR 300 page 9 of 28 4.3.7 Connecting a counter signal When configuring the device you can select 3 different input signal modes similar to the connection of frequency- rotation-signals. The connection of a sensor-signal for a counter-signal is the same used for the frequency- and rotation-signal.
E44.X.00.6C-03 Connection and operating manual GIR 300 page 10 of 28 4.4 Connecting switching outputs In order to avoid unwanted or wrong switching processes, we suggest to connect the device’s Hint: switching outputs after you have configured the device’s switching outputs properly.
E44.X.00.6C-03 Connection and operating manual GIR 300 page 11 of 28 Configuration Please note: When you are configuring the device and don’t press any button for more than 60 sec. the configuration of the device will be cancelled. The changes you made will not be saved and will be lost! The buttons 2 and 3 are featured with a ‘roll-function‘.
E44.X.00.6C-03 Connection and operating manual GIR 300 page 12 of 28 Parameter Overflow for the available measuring types: T.RES T.TC FREQ [O.VP [O.DN SER, Measuring type Input signal / sensor Signal edge Devisor Input signal low Input signal high Decimal point...
Page 13
E44.X.00.6C-03 Connection and operating manual GIR 300 page 13 of 28 Press button 1 again. The display will show “Li“ (Limit = Measuring range limit). Use button 2 and button 3 to select the desired measuring range limit. Display Measuring range limit...
E44.X.00.6C-03 Connection and operating manual GIR 300 page 14 of 28 (Pt 100, Pt 1000 RTD probes and thermocouples type J, K, N, S or T) 5.3 Measuring temperature This chapter describes how to configure the device for temperature measuring with the help of external platinum RTD probes or thermocouple probes.
E44.X.00.6C-03 Connection and operating manual GIR 300 page 15 of 28 5.4 Measuring of frequency (TTL, switching-contact) This chapter describes how to configure the device for measuring frequency. This instruction demands that you selected “FrEq“ as your desired input type like it is explained in chapter 5.1.
E44.X.00.6C-03 Connection and operating manual GIR 300 page 16 of 28 The measuring range is exactly bounded by the selected frequency-measuring-range-limit. When exceeding or shortfalling of the limit the (displays the selected limit) on.rG Active, device will display the lower or upper display- range-limit.
E44.X.00.6C-03 Connection and operating manual GIR 300 page 17 of 28 With the decimal point position on --.-- the device will display something like 49.99 – 50.00 – 50.01, but the maximum value that can be displayed is 99.99 rotations per minute.
Page 18
E44.X.00.6C-03 Connection and operating manual GIR 300 page 18 of 28 Example 2: Your transmitter is supplying about 5 000 000 pulses during the measurement, which ex- ceeds the limit of the device. But when setting a pre-scaling factor of 1000 only every 1000th pulse is used for further processing.
E44.X.00.6C-03 Connection and operating manual GIR 300 page 19 of 28 5.7 Interface mode When the device is in the interface mode it won’t make any measurements by itself. The value shown in the device’s display is sent via serial interface.
Page 20
E44.X.00.6C-03 Connection and operating manual GIR 300 page 20 of 28 Press button 1 to validate the selected output function. The display shows “outP“ again. Depending on your output function setting, it may be possible that one or more settings described below won’t be available.
E44.X.00.6C-03 Connection and operating manual GIR 300 page 21 of 28 Switching points and alarm-boundaries Note: All relevant switching and alarm points can be set at this menu. (Preferred output position and delay of the output can only be set at configuration menu) Depending on the selected output function different parameters have to be adjusted.
E44.X.00.6C-03 Connection and operating manual GIR 300 page 22 of 28 6.1 2-point-controller, 3-point-controller This chapter describes how to configure the device as a 2-point-controller or 3-point-controller. This instruction demands that you selected “2P“ or “3P“ as your desired output function like it is explained in chapter 5.8.
E44.X.00.6C-03 Connection and operating manual GIR 300 page 23 of 28 When pressing button 1 again, the device will be displaying “A.dEL“. (delay of the alarm-function) A.DEL Use button 2 and button 3 to set the desired delay of the alarm-function.
E44.X.00.6C-03 Connection and operating manual GIR 300 page 24 of 28 Offset- and slope-adjustment The offset and slope-adjustment function can be used for compensating the tolerance of the used sensor, and for vernier adjustment of the used transducer or transmitter.
E44.X.00.6C-03 Connection and operating manual GIR 300 page 25 of 28 Min-/max-value memory The device features a minimum/maximum-value storage. In this storage the highest and lowest performance data is saved. Calling of the minimum value: the device will display “Lo“ briefly, after that the min-value is displayed for about 2 sec.
Page 26
E44.X.00.6C-03 Connection and operating manual GIR 300 page 26 of 28 Err.3 Display range has been exceeded Indicates that the valid display range (9999 digit) of the device has been exceeded. Possible causes: - Incorrect scale. - Counter overflow Remedies: - The error-message will be reset if the display value is below 9999.
E44.X.00.6C-03 Connection and operating manual GIR 300 page 27 of 28 11 Specification Absolute maximum ratings: see chapter 4.2 Measuring inputs: Standard inputs for Input type Input signal Measuring range Resolution Note 0 – 10 V Standard 0 ... 10 V Ri >...
E44.X.00.6C-03 Connection and operating manual GIR 300 page 28 of 28 Measuring freq.: approx. 100 measures / sec. (standard-signal) or approx. 4 measures / sec. (temperature-measurement) or approx. 4 measures / sec. (frequency, rpm at f > 4 Hz) or accordingly f (at f < 4 Hz)