GREISINGER GIR 300 Operating Manual

Universal displaying and controlling device

Advertisement

Quick Links

E44.X.01.6C-03
Universal displaying and controlling device
GIR 300
Operating Manual
as of Version 1.1
WEEE-Reg.-Nr. DE 93889386
GHM Messtechnik GmbH • Standort Greisinger
Hans-Sachs-Str. 26 • D-93128 Regenstauf
+49 (0) 9402 / 9383-0
+49 (0) 9402 / 9383-33
info@greisinger.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GIR 300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GREISINGER GIR 300

  • Page 1 E44.X.01.6C-03 Universal displaying and controlling device GIR 300 Operating Manual as of Version 1.1 WEEE-Reg.-Nr. DE 93889386 GHM Messtechnik GmbH • Standort Greisinger Hans-Sachs-Str. 26 • D-93128 Regenstauf    +49 (0) 9402 / 9383-0 +49 (0) 9402 / 9383-33...
  • Page 2: Table Of Contents

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 2 of 28 Index GENERAL NOTE ..............................3 INTENDED USE ................................ 3 SAFETY ..................................4 ..........................4 AFETY SIGNS AND SYMBOLS .............................. 4 AFETY GUIDELINES ............................. 4 KILLED PERSONNEL ELECTRIC CONNECTION ............................5 ............................
  • Page 3: General Note

    EASYBus-module. When leaving our factory the GIR 300 has been subjected to various inspection tests and is completely calibrated. Before the GIR 300 can be used, it has to be configured for the customer’s application.
  • Page 4: Safety

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 4 of 28 Safety 3.1 Safety signs and symbols Warnings are labeled in this document with the followings signs: Caution! This symbol warns of imminent danger, death, serious injuries and significant damage to property at non-observance.
  • Page 5: Electric Connection

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 5 of 28 Electric connection  Wiring and commissioning of the device must be carried out by trained and skilled personnel only. Wrong connection may lead to the destruction of the display device, in which case we cannot assume any...
  • Page 6: Connection An Input Signal

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 6 of 28 4.3 Connection an input signal  Please take care not to exceed the limitations of the inputs when connecting the device as this may lead to destruction of the device.
  • Page 7: Connecting A 0-1V, 0-2V Or 0-10V Transmitter In 3-Wire-Technology

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 7 of 28 4.3.4 Connecting a 0-1V, 0-2V or 0-10V transmitter in 3-wire-technology Supply: for transmitter 0-1(10)V Sig. Transmitter 1V / 2V 1V / 2V 0-1(10)V Sig. Transmitter Supply: 9-28 VDC Supply:...
  • Page 8 E44.X.00.6C-03 Connection and operating manual GIR 300 page 8 of 28 Supply: for transducer Sig. Transducer Sig. Transducer Supply: 9-28 VDC Supply: 9-28 VDC Connection of a transducer (with separate power Connection of a transducer (without separate power supply) with TTL or PNP output...
  • Page 9: Connecting A Counter Signal

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 9 of 28 4.3.7 Connecting a counter signal When configuring the device you can select 3 different input signal modes similar to the connection of frequency- rotation-signals. The connection of a sensor-signal for a counter-signal is the same used for the frequency- and rotation-signal.
  • Page 10: Connecting Switching Outputs

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 10 of 28 4.4 Connecting switching outputs In order to avoid unwanted or wrong switching processes, we suggest to connect the device’s Hint: switching outputs after you have configured the device’s switching outputs properly.
  • Page 11: Configuration

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 11 of 28 Configuration Please note: When you are configuring the device and don’t press any button for more than 60 sec. the configuration of the device will be cancelled. The changes you made will not be saved and will be lost! The buttons 2 and 3 are featured with a ‘roll-function‘.
  • Page 12: Measuring Voltage Or Current

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 12 of 28 Parameter Overflow for the available measuring types: T.RES T.TC FREQ [O.VP [O.DN SER, Measuring type Input signal / sensor Signal edge Devisor Input signal low Input signal high Decimal point...
  • Page 13 E44.X.00.6C-03 Connection and operating manual GIR 300 page 13 of 28 Press button 1 again. The display will show “Li“ (Limit = Measuring range limit). Use button 2 and button 3 to select the desired measuring range limit. Display Measuring range limit...
  • Page 14: Measuring Temperature (P T 100, P T 1000 Rtd Probes And Thermocouples Type J, K, N, Sor T)

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 14 of 28 (Pt 100, Pt 1000 RTD probes and thermocouples type J, K, N, S or T) 5.3 Measuring temperature This chapter describes how to configure the device for temperature measuring with the help of external platinum RTD probes or thermocouple probes.
  • Page 15: Measuring Of Frequency (Ttl, Switching-Contact)

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 15 of 28 5.4 Measuring of frequency (TTL, switching-contact) This chapter describes how to configure the device for measuring frequency. This instruction demands that you selected “FrEq“ as your desired input type like it is explained in chapter 5.1.
  • Page 16: Measuring Of Rotation Speed (Ttl, Switching-Contact)

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 16 of 28 The measuring range is exactly bounded by the selected frequency-measuring-range-limit. When exceeding or shortfalling of the limit the (displays the selected limit) on.rG Active, device will display the lower or upper display- range-limit.
  • Page 17: Up-/Downwards Counter

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 17 of 28 With the decimal point position on --.-- the device will display something like 49.99 – 50.00 – 50.01, but the maximum value that can be displayed is 99.99 rotations per minute.
  • Page 18 E44.X.00.6C-03 Connection and operating manual GIR 300 page 18 of 28 Example 2: Your transmitter is supplying about 5 000 000 pulses during the measurement, which ex- ceeds the limit of the device. But when setting a pre-scaling factor of 1000 only every 1000th pulse is used for further processing.
  • Page 19: Interface Mode

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 19 of 28 5.7 Interface mode When the device is in the interface mode it won’t make any measurements by itself. The value shown in the device’s display is sent via serial interface.
  • Page 20 E44.X.00.6C-03 Connection and operating manual GIR 300 page 20 of 28 Press button 1 to validate the selected output function. The display shows “outP“ again. Depending on your output function setting, it may be possible that one or more settings described below won’t be available.
  • Page 21: Switching Points And Alarm-Boundaries

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 21 of 28 Switching points and alarm-boundaries Note: All relevant switching and alarm points can be set at this menu. (Preferred output position and delay of the output can only be set at configuration menu) Depending on the selected output function different parameters have to be adjusted.
  • Page 22: 2-Point-Controller, 3-Point-Controller

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 22 of 28 6.1 2-point-controller, 3-point-controller This chapter describes how to configure the device as a 2-point-controller or 3-point-controller. This instruction demands that you selected “2P“ or “3P“ as your desired output function like it is explained in chapter 5.8.
  • Page 23: Minimum/Maximum Alarm (Individual Or Common)

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 23 of 28 When pressing button 1 again, the device will be displaying “A.dEL“. (delay of the alarm-function) A.DEL Use button 2 and button 3 to set the desired delay of the alarm-function.
  • Page 24: Offset- And Slope-Adjustment

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 24 of 28 Offset- and slope-adjustment The offset and slope-adjustment function can be used for compensating the tolerance of the used sensor, and for vernier adjustment of the used transducer or transmitter.
  • Page 25: Min-/Max-Value Memory

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 25 of 28 Min-/max-value memory The device features a minimum/maximum-value storage. In this storage the highest and lowest performance data is saved. Calling of the minimum value: the device will display “Lo“ briefly, after that the min-value is displayed for about 2 sec.
  • Page 26 E44.X.00.6C-03 Connection and operating manual GIR 300 page 26 of 28 Err.3 Display range has been exceeded Indicates that the valid display range (9999 digit) of the device has been exceeded. Possible causes: - Incorrect scale. - Counter overflow Remedies: - The error-message will be reset if the display value is below 9999.
  • Page 27: Specification

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 27 of 28 11 Specification Absolute maximum ratings: see chapter 4.2 Measuring inputs: Standard inputs for Input type Input signal Measuring range Resolution Note 0 – 10 V Standard 0 ... 10 V Ri >...
  • Page 28: Reshipment And Disposal

    E44.X.00.6C-03 Connection and operating manual GIR 300 page 28 of 28 Measuring freq.: approx. 100 measures / sec. (standard-signal) or approx. 4 measures / sec. (temperature-measurement) or approx. 4 measures / sec. (frequency, rpm at f > 4 Hz) or accordingly f (at f < 4 Hz)