GREISINGER GIR 230 Pt1000 / DIF Manual For Connection And Operation

Advertisement

Quick Links

E33.0.31.6C-02
Manual for connection and operation of the GIR230 Pt1000 / DIF and GIR230 NTC /DIF
Page 1 of 14
Manual for connection and operation of
GIR 230 Pt1000 / DIF
GIR 230 NTC / DIF
Version 1.3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GIR 230 Pt1000 / DIF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GREISINGER GIR 230 Pt1000 / DIF

  • Page 1 E33.0.31.6C-02 Manual for connection and operation of the GIR230 Pt1000 / DIF and GIR230 NTC /DIF Page 1 of 14 Manual for connection and operation of GIR 230 Pt1000 / DIF GIR 230 NTC / DIF Version 1.3...
  • Page 2: Table Of Contents

    E33.0.31.6C-02 Manual for connection and operation of the GIR230 Pt1000 / DIF and GIR230 NTC /DIF Page 2 of 14 Index 1. SAFETY REGULATIONS ............................3 2. INTRODUCTION ................................ 4 3. ELECTRICAL CONNECTION..........................4 3.1. Terminal assignment..............................4 3.2. Connection data ............................... 4 3.3.
  • Page 3: Safety Regulations

    E33.0.31.6C-02 Manual for connection and operation of the GIR230 Pt1000 / DIF and GIR230 NTC /DIF Page 3 of 14 1. Safety regulations This device was designed and tested considering the safety regulations for electronic measuring devices. Faultless operation and reliability in operation of the measuring device can only be assured if the General Safety Measures and the devices specific safety regulations mentioned in this users manual are considered.
  • Page 4: Introduction

    E33.0.31.6C-02 Manual for connection and operation of the GIR230 Pt1000 / DIF and GIR230 NTC /DIF Page 4 of 14 2. Introduction GIR230 Pt1000 / DIF and the GIR230 NTC / DIF is a microprocessor controlled displaying, monitoring and controlling device. The device is supporting two interface for the connection of: - Pt1000 (2-wire-technology) at type GIR230 Pt1000 / DIF...
  • Page 5: Connecting An Input Signal

    E33.0.31.6C-02 Manual for connection and operation of the GIR230 Pt1000 / DIF and GIR230 NTC /DIF Page 5 of 14 3.3. Connecting an input signal Please take care not to exceed the limitations of the inputs when connecting the device as this may lead to destruction of the device..
  • Page 6: Configuration Of The Device

    E33.0.31.6C-02 Manual for connection and operation of the GIR230 Pt1000 / DIF and GIR230 NTC /DIF Page 6 of 14 4. Configuration of the device Please note: When you are configuring the device and don’t press any button for more than 60 sec. the configuration of the device will be cancelled.
  • Page 7: Selection Of The Output Function

    E33.0.31.6C-02 Manual for connection and operation of the GIR230 Pt1000 / DIF and GIR230 NTC /DIF Page 7 of 14 4.2. Selection of the output function The Display now shows “outP“. (output) Use button 2 and button 3 (middle and right button) to select the desired output-function. The following table shows how the outputs will be configured on your selection.
  • Page 8: Switchpoints And Alarm-Boundaries

    E33.0.31.6C-02 Manual for connection and operation of the GIR230 Pt1000 / DIF and GIR230 NTC /DIF Page 8 of 14 5. Switchpoints and alarm-boundaries Please note: The settings of the switchpoints will be cancelled, when no button was pressed for more than 60 sec.
  • Page 9: 2-Point-Controller With Alarm Function, 3-Point-Controller With Alarm Function

    E33.0.31.6C-02 Manual for connection and operation of the GIR230 Pt1000 / DIF and GIR230 NTC /DIF Page 9 of 14 Now you finished configuring the switching points of your device. Press button 1 to switch over to display the measuring value. 5.2.
  • Page 10: Minimum/Maximum-Alarm

    E33.0.31.6C-02 Manual for connection and operation of the GIR230 Pt1000 / DIF and GIR230 NTC /DIF Page 10 of 14 5.3. Minimum/maximum-alarm This chapter describes how to configure the device‘s alarm boundaries for min-/max-alarm-monitoring. This instruction demands that you selected “AL“ as your desired output function. Press button 1 , the device will be displaying “AL.Hi“.
  • Page 11: Offset- And Slope-Adjustment

    E33.0.31.6C-02 Manual for connection and operation of the GIR230 Pt1000 / DIF and GIR230 NTC /DIF Page 11 of 14 9. Offset- and slope-adjustment The offset and slope-adjustment function can be used for compensating the tolerance of the used probes. Please note: The settings of the offset- / slope-adjustment will be cancelled, when no button was pressed for more than 60 sec.
  • Page 12: Error Codes

    E33.0.31.6C-02 Manual for connection and operation of the GIR230 Pt1000 / DIF and GIR230 NTC /DIF Page 12 of 14 10. Error codes When detecting an operating state which is not permissible, the device will display an error code The following error codes are defined: Err.1: Exceeding of the measuring range Indicates that the valid measuring range of the device has been exceeded.
  • Page 13: Specification

    0 Ω ∞ Ω 8, 6 and 7 probe Absolute maximum ratings must not be exceeded (not even for a short period of time)! GIR 230 Pt1000 / DIF GIR 230 NTC / DIF Measuring inputs: Pt1000 (2-wire) NTC (2-wire) Display range: -200 ...
  • Page 14 E33.0.31.6C-02 Manual for connection and operation of the GIR230 Pt1000 / DIF and GIR230 NTC /DIF Page 14 of 14...

This manual is also suitable for:

Gir 230 ntc / dif

Table of Contents