ZSE40A ( F ) /ISE40A
Series

Function Details

J
Power-saving mode (F80)
Power-saving mode can be selected.
It shifts to the power-saving mode without button operation for 30
seconds. It is set to the normal mode (Power-saving mode is OFF.)
when ex-factory. (Decimal points and operation indicator light (only
when the switch output is turned ON.) blink in the power-saving
mode.)
K
Setting of secret code (F81)
Users can select whether a secret code must be entered to release
key lock. At the time of shipment from the factory, it is set such that
the secret code is not required.
L
Auto-shift function (F5)
When there are large fluctuations in the supply pressure, the switch
may fail to operate correctly. The auto-shift function compensates
such supply pressure fluctuations. It measures the pressure at the
time of auto-shift signal input and uses it as the reference pressure
to correct the set-value on the switch.
Set-value correction by auto-shift function
Supply pressure
normal
P - 1
(P - 3)
H - 1
(H - 2)
Switch
ON
output
OFF
1·(2)
5 ms or more
Hi
Auto-shift
input
Lo
∗ Rectified value
When the auto-shift is selected, "
second, and the pressure value at that point will be saved as a recti-
fied value "
". Based on the saved rectified values, the set-value
of "
", "
", "
", and "
Note) When an output is reversed, "
rectified.
Settable Range for Auto-Shift Input
Set pressure range
Compound pressure
–105.0 to 105.0 kPa
Vacuum pressure
10.0 to –105.0 kPa
Positive pressure
–0.105 to 1.050 MPa
Auto-shift zero
The basic function of auto-shift zero is the same as the function for
auto-shift. Also, it corrects values on the display, based on a pres-
sure value of " ", when the auto-shift is selected.
35
Supply pressure
Supply pressure
drop
increase
Rectified value ∗
A
B
Switch output
10 ms or less
response time
when auto-
shift is input.
" will be displayed for about 1
" will likewise be rectified.
", "
", "
", "
" will be
Settable range
–210 to 210 kPa
115.0 to –115.0 kPa
–1.155 to 1.155 MPa
The F  in ( ) shows the function code number. Refer to the operation
manual for the details of operation procedures and function codes.
Connection examples of auto shift
Output specification: -R/-S
NPN (2 outputs) + Auto-shift input
Pressure Switch
Output specification: -T/-V
PNP (2 outputs) + Auto-shift input
Pressure Switch
Note)
Brown DC(+)
Gray Auto-shift input
+
12 to
Black OUT1
24 VDC
White OUT2
Blue DC(–)
Brown DC(+)
Gray Auto-shift input
Black OUT1
+
12 to
24 VDC
White OUT2
Blue DC(–)