CH5612 & CH5624
Automatic Battery Charger user manual
GENERAL INFORMATION
A visual inspection of this product for damage during
shipping is recommended before installation. Please
contact your local supplier with any questions.
SECTION
1:
INSTRUCTIONS
This manual contains important safety and operating
instructions for battery charger Models CH5612 and
CH5624. Read the manual carefully and follow the
instructions before using your charger.
High Voltage may result in a risk of fire, electric
shock, injury or death.
WARNING
Batteries may generate explosive gases during
normal operation and charging. Never smoke,
light a flame, or generate any sparks near the
battery.
SECTION 2: SPECIFICATIONS
Power Input
100 265 Vac
Voltage
47 63 Hz
Frequency
Current
2A
DC Output
CH5612
Voltage 13.8 Vdc / Current 12A Max.
CH5624
Voltage 27.6 Vdc / Current 6A Max.
DC Voltage Regulation
Less than +/- 1%
Charge Mode
Float (Current limiting, constant voltage)
Efficiency
More than 88% @ Full load
Static Power Consumption
Max 3.5W @ 110 Vac
Max 4.5W @ 220 Vac
Fuse
Slow blow 5A 300V
Suitable Battery Type
Gel, Lead Acid & AGM
___________________________________________________________________________________________
CH56
IMPORTANT
SAFETY
DANGER
1.1 This is not a power supply. Use only as a battery
charger.
1.2 Built-in AC power fuses protected input. No
external fuses are needed. Do not attempt to
replace internal fuse, if it burns out.
1.3 Do not expose the battery charger to rain, snow or
wet environments.
1.4 Do not disassemble the charger. Return to
supplier when service and repair is needed.
1.5 Be very careful not to drop any metal tool on to the
battery or charger. It may spark or short-circuit the
battery or other electrical part, which in turn may
cause an explosion.
1.6 To reduce the risk of damage to the electric plug
and cord, pull using the plug rather than the cord
when disconnecting the charger.
1.7 If battery acid or chemicals contact skin or
clothing,wash immediately with soap and water.
1.8 If battery acid or chemicals comes into contact
with your eye, immediately begin washing your
eye with cold water before taking any other action
and continue for at least 10 minutes. Get
immediate medical attention.
Protection
Reverse polarity & short circuit protections
DC output Over/Under Voltage protections
DC output Over Current protection
AC input Over Voltage protection
Temperature sensor failure protection
Environment
Operation Temperature
Storage Temperature
Relative Humidity
Vibration
Mounting Type
Panel Mount
Dimensions
208.0 (L) x 134.0 (W) x 63.0 (H) mm
8.19" (L) x 5.28" (W) x 2.48" (H)
Weight
0.89 Kg (1.96 Lbs) +/- 2%
-20 to +60 ˚C
-30 to +80 ˚C
Max. 90%
5.0Gs @ 60 Hz
1
Need help?
Do you have a question about the CH5612 and is the answer not in the manual?
Questions and answers