MMM Group VACUCELL 22 Instructions For Use Manual

MMM Group VACUCELL 22 Instructions For Use Manual

Vacuum cabinets - line standard

Advertisement

Instructions for use
Vacuum cabinets - line Standard
VACUCELL
22, 55, 111
VACUCELL-S_np_en_1105_mmm_V2.07_B2V

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VACUCELL 22 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MMM Group VACUCELL 22

  • Page 1 Instructions for use Vacuum cabinets - line Standard VACUCELL 22, 55, 111 VACUCELL-S_np_en_1105_mmm_V2.07_B2V...
  • Page 2 Congratulations on obtaining a new temperature cabinet, Temperaturesensitive,easy decomposable or oxidative materials, can be dried very tenderly in VACUCELL, vacuun drying ovens, vhere is the opportunity of extrusion of air by inert gas. Also complicated components with hardly accessible hollow spaces are drying quick and affectivelly in VACUCELL ovens.
  • Page 3: Table Of Contents

    CONTENTS: 18. 5. 2011 GENERAL INFORMATION.........................3 .........................3 COPE OF VALIDITY ............................3 URPOSE ..............................3 IMPORTANT INSTRUCTIONS......................3 .................3 NPACKING CHECKING TRANSPORT AND HANDLING .......................3 EFORE PUTTING INTO OPERATION ..........................4 SEFUL SPACE ......................4 IRING AND OTHER CONDITIONS DESCRIPTION OF THE UNIT......................5 ..........................5 ENERAL VIEW .....................5 ONTROL PANEL IN THE DOOR OF THE BOX ....................6...
  • Page 4 OPTIONS............................15 11.1 .......................15 UPPORTIVE SW FOR PC 11.2.1 ............15 ECORDING SW WARMCOMM FOR PC UNDER WINDOWS 11.2.2 ........15 ECORDING PRINTING SW PRINTER ARCHIV FOR PC UNDER WINDOWS 11.2 „ “........................15 VACUSTATION 11.3 ....................16 HEMICALLY RESISTANT VACUUM PUMP 11.4 .....................16 EPARATOR AND EMISSION CONDENSER 11.5 ......................16 NDEPENDENT PT 100 SENSOR...
  • Page 5: General Information

    Instructions for use GENERAL IMPORTANT INFORMATION INSTRUCTIONS SCOPE OF VALIDITY UNPACKING CHECKING TRANSPORT AND HANDLING These instructions apply to the device series VUS-B2V and VUS-B2V-M. After unpacking please check that the unit and the accessories are complete and undamaged). Possible damage must be immediately reported PURPOSE to the transporter.
  • Page 6: Useful Space

    Instructions for use USEFUL SPACE materials can be inserted to the unit! The Useful space is illustrated in Fig.1, where X(H) = same concerns also materials material 10% of the interior chamber depth, X(Š) = 10% of giving off such a stuff! the interior chamber width, X(V) 1 is the distance The unit is not designed to warm-up liquids od the lowest shelve from the bottom of interior...
  • Page 7: Description Of The Unit

    Instructions for use DESCRIPTION OF THE CONTROL PANEL IN THE DOOR OF THE BOX UNIT GENERAL VIEW Fig. 3 1 - Display 2 - Decimal point - lights (the unit is connected to the mains - stand-by condition) 3 - Preselected programs indicator lamps- lights: program is active - blinks: program will be active in 5 sec.
  • Page 8: Control Panel In The Superstructure

    Instructions for use 9 pin Canon connector on the case CONTROL PANEL IN THE SUPERSTRUCTURE Signal 25 pin Canon connector in the printer Signal Fig. 4 1 - Mains main switch indicator 2 - Mains main switch 3 - Ball valve connecting the chamber and the Ovens connected by RS-232C connector vacuum pump, in position ON is valve open must meet the regulations and be approved...
  • Page 9: Switching On

    Instructions for use U2 – (CYcl) On or OFF – cycles permit or The functions of the respective indicator lights prohibition are set by means of are described in chapter 3 - Description of the (for all pre-sets at once); a cycle means a Unit, and 3.3 - Control Panel.
  • Page 10: And Time - Delayed Switching - On

    Instructions for use -99.9 °C, or the function can be switched cycles – see Chapter 4.3). All indicators will off, which is displayed as “OFF”. The alarm function has been switched off as a default. the time-delayed switching-off. Select the possibility of the cycles setting by means of U15 –...
  • Page 11: List Of Error Messages

    Instructions for use too close (up to 3 °C) to the user safety upper LIST OF ERROR MESSAGES temperature checked by the safety system (U6), When there is an error announced on the dis- which probably will cause the safety system play, you can use the buttons switch to activation.
  • Page 12: Protocol Printing

    Instructions for use The temperature never reaches the required printing. The interval is shown in the record value during the exposure cycle. Check whether heading. The printer interval can be set on the display in the Instructions for Use, chapter Power Mains in the range from Connection.
  • Page 13: Change Of The Maximum And Minimum Values

    Instructions for use - maximum permitted temperature after the damaging or destruction of material samples termination of cooling. It reaches the T exp max in case of the temperature regulator damage, or temperature or 55 °C, whichever is lower. unintended setting of a higher temperature than that tolerated by the sample in the unit chamber).
  • Page 14: Creation Of Vacuum In The Chamber

    Instructions for use value 5 °C over the required temperature. The safety circuit must react. LED of the safety thermostat is switched on and Er12 error is displayed. CREATION OF VACUUM IN THE CHAMBER Push the hose from the vacuum pump onto the end of the vacuum piping of the unit (Fig.2, position 11) which is accessible through the side cut-out in the superstructure.
  • Page 15: Specifications Of The Unit

    Instructions for use SPECIFICATIONS OF THE UNIT VACUCELL (VU) Te c h n i c a l d a t a volume cca ltrs Interior of stainless steel width cca mm material DIN 1.4571(AISI316TI) depths cca mm height cca mm Shelves Shelves wiring number max.
  • Page 16: Cleaning

    Instructions for use WARRANTY CLEANING CONDITIONS Cleaning is to be performed only after cooling the unit down and after disconnection of the AND SERVICE mains cord from the mains. Internal walls of the chamber and the surface of the unit is to be GUARANTEED cleaned with water and detergent or suitable chemical means, it is necessary to use rags that...
  • Page 17: Method Of Liquidation Of The Packing And Of The Discarded Unit

    Instructions for use (for instance to repair or in case of reclamation), OPTIONS use the original package. Otherwise you take responsibility for possible damaging during the transport and producer will claim the costs for 11.1 SUPPORTIVE SW FOR PC appropriate repairing of you. The device shall be stored in the range of temperatures from 0 °C to 11.1.1 RECORDING SW...
  • Page 18 Note Instructions for use on the pump outlet and reduces the amount of emissions of the exhausted gas/steam in the outer space. Both parts are made of glass and 11.5 PT100 INDEPENDENT SENSOR This is another additional sensor, freely movable in the chamber. Temperature inside the chamber or in the material can be measured by means of it.
  • Page 19 (XURSHDQ 'LUHFWLYH (& (& 000 0HGFHQWHU (LQULFKWXQJHQ *PE+ 6HPPHOZHLVVWUDVVH  ' 3ODQHJJ  0QFKHQ GHFODUH RQ RXU RZQ UHVSRQVLELOLW\ WKDW SURGXFW HOHFWULFDOO\ KHDWHG ODERUDWRU\ RYHQ LQWHQGHG IRU PDWHULDO KHDWLQJ LQ WKH WHPSHUDWXUH UDQJH XS WR  ƒ& ZLWK GU\LQJ RYHQ SRVVLEOH HYDFXDWLRQ RI WKH FKDPEHU RU SRVVLEOH XVDJH RI LQHUW JDV LQ WKH FKDPEHU 9$&8&(// WUDGH QDPH...