Note
The SCSI bus
number
corresponds to
the physical SCSI
port on the back
of the FCR200.
Indexed Addressing
5-6
Understanding the Configuration
Auto Addressing
SCC Addressing
SCSI Targets are selected by mapping the appropriate values
into the FCP LUN field, and correlating a Fibre Channel LUN
value to a SCSI Bus:Target:LUN value. The FCR200 acts as a
single initiator on each SCSI bus, defaulting to ID 7. All
commands passed through to a SCSI bus originate from this
SCSI ID.
As an example, SCSI bus 0 corresponds to SCSI port 0 on the
rear of the FCR200. SCSI bus 1 corresponds to SCSI port 1.
Indexed Addressing allows for generic Fibre Channel host
bus adapters to access SCSI devices attached to the FCR200.
This is done by use of a table which is indexed by sequential
FCP LUN values, indicating selected BUS:TARGET:LUN
devices.
Table 5-1
Indexed Addressing
FPC LUN Value
0
1
2
3
4
5
6
7
(...)
Automatically creates a new address
mapping table every time the
FCR200 is power cycled.
Implements the SCSI-3 Controller
Commands SCSI storage array
addressing to address SCSI devices
attached to the FCR200.
SCSI BUS:TARGET:LUN
0:0:0
0:1:0
0:2:0
0:3:0
0:4:0
0:5:0
0:6:0
0:7:0 occupied by initiator ID
0:8:0
(...)
62-9301-01