Haier HW90-BP14636 User Manual page 23

Hide thumbs Also See for HW90-BP14636:
Table of Contents

Advertisement

Available languages

Available languages

GB
Problem
Cause
• Temperature sensor - error..
F3
• Heating error
F4
• Motor - error..
F7
• Water level sensor - error
FA
• Abnormal communication error
FC1 or
FC2
• Unbalanced load - error..
UNB
9.3 Troubleshooting without display code
Problem
Washing machine fails
to operate.
Washing
machine
will not be filled with
water.
Machine is draining
while being filled.
Drainage failure.
Strong vibration while
spinning.
Operation stops
before completing
wash cycle.
Operation stops for
a period of time.
Cause
• Programme is not yet started.
• Door is not properly closed.
• Machine has not been switched on.
• Power failure.
• Child lock is activated.
• No water.
• Inlet hose is kinked.
• Inlet hose filter is blocked.
• Water pressure is less than 0.03 MPa.
• Door is not properly closed.
• Water supply failure.
• Height of drain hose is below 80 cm.
• Drain hose end could reach into
water.
• Drain hose is blocked.
• Pump filter is blocked.
• Drain hose end is higher than 100 cm
above floor level.
• Not all transportation bolts have
been removed.
• Appliance has no solid position.
• Machine load is not correct.
• Water or electric failure.
• Appliance displays error code.
• Problem due to load pattern.
• Programme performs soaking cycle.
9-Troubleshooting
Solution
• Contact the After sales service..
• Contact the After sales service..
• Contact the After sales service..
• Contact the After sales service..
• Contact the After sales service..
• Check and balance laundry load in the drum.
Reduce the load.
Solution
• Check programme and start it.
• Close the door properly.
• Switch the machine on.
• Check power supply.
• Deactivate child lock.
• Check water tap.
• Check inlet hose.
• Unblock inlet hose filter.
• Check water pressure.
• Close the door properly.
• Ensure the water supply.
• Make sure that drain hose is
properly installed.
• Make sure the drain hose is not
in water.
• Unblock drain hose.
• Clean pump filter.
• Make sure that drain hose is
properly installed.
• Remove all transportation bolts.
• Ensure solid ground and a levelled
position.
• Check load weight and balance.
• Check power and water supply.
• Consider display codes.
• Reduce or adjust load.
• Cancel programme and restart.
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hw90-b14636

Table of Contents