Table for the Choice of the Injectors
Large Burner (Fast)
Standard Burner
Small Burner (Simmer)
Top Oven Burner
Main Oven Burner
• All intervention regarding installation maintenance and conversion of the appliance must be
fulfilled with original factory parts.
• The manufacturer declines any liability if these correct parts are not used.
Kenwood Free Standing Double Oven Gas Cooker KDG606S19 Manual.indd 37
Kenwood Free Standing Double Oven Gas Cooker KDG606S19 Manual.indd 37
Burner Injector Values
According To The Gas Type
Injector
Gas Flow
(15°C and 1013mbar)
Power
Injector
Gas Flow
(15°C and 1013mbar)
Power
Injector
Gas Flow
(15°C and 1013mbar)
Power
Injector
Gas Flow
(15°C and 1013mbar)
Power
Injector
Gas Flow
(15°C and 1013mbar)
Power
LPG
G 30/31
28-30/37 mBar
mm
0.850
218.10 gr/h
kW
3.000
mm
0.650
127.20 gr/h
kW
1.750
mm
0.500
72.70 gr/h
kW
1.000
mm
0.750
174.50 gr/h
kW
2.400
mm
0.750
174.50 gr/h
kW
2.400
Natural Gas
G 20
20 mBar
1.150
276.00 lt/h
2.900
0.970
166.70 lt/h
1.750
0.720
95.20 lt/h
1.000
1.150
228.60 lt/h
2.400
1.150
228.60 lt/h
2.400